My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-00101 - mechanical
Orono
>
Property Files
>
Street Address
>
E
>
Elmwood Avenue
>
1161 Elmwood Avenue - 07-117-23-14-0073 - New PID
>
Permits/Inspections
>
2014-00101 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:31:58 PM
Creation date
7/27/2016 2:34:50 PM
Metadata
Fields
Template:
x Address Old
House Number
1161
Street Name
Elmwood
Street Type
Avenue
Address
1161 Elmwood Ave
Document Type
Permits/Inspections
PIN
0711723140073
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential 8 Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Sabre Plumbing&Heating � Sundberg-1161 Elmwood Ave Orono <br /> _Ply_mouth,MN_ 55447 _ Page 2 <br /> Project Report <br /> - - - - _ _ == = - _-_ _- _ - - - _ _ --- <br /> General Proiect Information L � I <br /> __ — ----- _ _ — <br /> Project Title: Sundberg- 1161 Elmwood Ave Orono ' <br /> Designed By: Todd Boyum , <br /> Project Date: 11/26/2013 <br /> Client Name: Colfax Companies ' <br /> � Client City: Wayzata, MN <br /> Company Name: Sabre Plumbing&Heating <br /> Company Representative: Todd Boyum <br /> Company Address: 15535 Medina Rd <br /> Company City: Plymouth, MN 55447 <br /> Company Phone: 763-473-2267 <br /> ' Company Fax: 763-473-8565 , <br /> Design Data _ _ _ - - - - ] � <br /> _ _ _ _ - - - - - - -- __ ___- .- - <br /> Reference City: Minneapolis, Minnesota <br /> Building Orientation: Front door faces West , <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum Rel.Hum � Bulb Difference <br /> Winter: -15 -12.38 n/a 30% 70 27.02 <br /> Summer. 90 73 45% 50°/a 75 32 <br /> Check_Figures - - - - - - - -- _ � _ - _ _ _ _ _ 1 <br /> Total Building Supply CFM: 1,332 CFM Per Square ft.: 0.447 <br /> Square ft. of Room Area: 2,978 Squa�e ft. Per Ton: 1,045 <br /> Volume(ft3) of Cond. Space: 26,243 <br /> Building Loads _ _ . _ _ _ _ _. _ _ <br /> ' Total Heating Required Including Ventilation Air: 62,402 Btuh 62.402 MBH <br /> Total Sensible Gain: 28,425 Btuh 83 % <br /> Total Latent Gain: 5,775 Btuh 17 % <br /> Total Cooling Required Including Ventilation Air: 34,201 Btuh 2.85 Tons(Based On Sensible+Latent) <br /> _ _ _ _ _ _ _ _ __ - - _ _ _ _ _ - <br /> Notes � <br /> _ - - ---- - _ _ _ _ _ _ - - - _ _ _ <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> ' All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at ' <br /> your design conditions. <br /> I <br /> C:\...\Colfax 1161 Elmwood Ave Orono.rh9 Tuesday, November 26, 2013, 4:19 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.