Laserfiche WebLink
�����y �1 r,a,��� ����' ���"f;: <br /> � ��Sch���°�� ����.��fi���,� ��ers�.�� ��._„�, � . , � �' <br /> � Com liance Certificate <br /> z� <br /> p <br /> Project Title: Cusick residence <br /> Energy Code: 20061ECC <br /> �ocation: Orono, Minnesota <br /> Construction Type: Single Family <br /> Conditioned Floor Area: 1992 ft2 <br /> Glazing Area Percentage: 13% <br /> Heating Degree Days: 8037 <br /> Climate Zone: s <br /> Construction Site: Owner/Agent: Designer/Contractor: <br /> 965 Edgewood Hills Road Cusick James L Patsch Construction,Inc. <br /> Orono,MN 3427 Humbolt Ave.S <br /> Minneapolis,MN 55408 <br /> - � <br /> �_:�.�:�^ <br /> Compliance:0.0%Better Than Code Maximum UA:208 Your UA:208 <br /> }.� �: :;:� <br /> .� ya<, . <br /> �y o a a i e <br /> �. <br /> ��,. - - m <br /> Basement Wall(garage):Masonry Block with Empty Cells 255 0.0 10A 14�� <br /> Wall height:9.0' <br /> Depth below grade:8.5' <br /> Insulation depth:9.0' <br /> Basement Wall 2:Solid Concrete or Masonry 90 13.0 0.0 6 <br /> Wall height:9.0' <br /> Depth below grade:7.0' <br /> Insulation depth:9.0' <br /> Wall 1:Wood Frame,16"o.c. 162 13.0 0.0 13 <br /> Wall 2:Wood Frame, 16"o.c. 468 19.0 0.0 25 <br /> Window 1:Metal Frame with Thertnal Break:Double Pane with 14 0.340 5 <br /> Low-E <br /> SHGC:0.31 <br /> Window 2 Fixed Unit:Metal Frame with Thermal Break:Double 35 0.290 10 <br /> Pane with Low-E <br /> SHGC:0.35 <br /> RIM:Wood Frame,16"o.c. 98 14.0 0.0 8 <br /> Wall 4:Wood Frame,16"o.c. 882 19.0 0.0 43 <br /> Window 3:Metal Frame:Double Pane with Low-E 143 0.340 49 <br /> SHGC:0.31 <br /> Window 4:Metal Frame with Thermal Break:Double Pane with 20 0.310 6 <br /> Low-E <br /> SHGC:0.32 <br /> Floor 1:All-Wood Joist/Truss:Over Outside Air 50 60.0 0.0 1 <br /> Ceiling 1:Raised or Energy Truss 1026 44.0 0.0 28 <br /> Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other <br /> calculations submitted with the permit application.The proposed building has been designed to meet the 2006 IECC requirements in <br /> REScheck Version 4.2.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. <br /> —_ . _ __ <br /> Name-Title Signature Date <br /> Project Notes: <br /> Master Bedroom Addition <br /> Project Title: Cusick residence Report date: 09/24/09 <br /> Data filename:C:1Users\KenlDocuments\Ken's1PlanWames L PatschlCusick\Cusick Res Check.rck Page 1 of 1 <br />