My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Preliminary Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road - (AKA: Co. Rd. 84)
>
3960 Bayside Road - 05-117-23-22-0016 - 2nd New PID
>
3960 Bayside Rd - 05-117-23-22-0007 - Old PID
>
Correspondence
>
Preliminary Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:19:57 PM
Creation date
7/7/2016 4:18:03 PM
Metadata
Fields
Template:
x Address Old
House Number
3960
Street Name
Bayside
Street Type
Road
Address
3960 Bayside Rd
Document Type
Correspondence
PIN
0511723220016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� 1NSPECTOR CHECKLIST - mound <br /> 3y6U tSays�cfe Kd., Urono <br /> � WELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> PROPERTY LINES setback: 10'to everything <br /> Road setback: platted: 10'prap tine. Metes & bounds: out of road easement, or oute�ditch. <br /> LAKE/BLUFF setback: 2d'for bluff. Lakes: GD_, RD_, NE Protected wetland_. <br /> Building setbacks: 10'for everything, 20'for dispersat area. <br /> WATER LINE under pressure se 10'to bed,tank�t sewer line. (else sewer line > 12"below) <br /> � Sewer line & baff[e connection (no 90's, 3'between 45's, slope min 1"in 8', max 2"in 8'} <br /> (no depth req's, clean out every 100', 5ch 44 pipe) <br /> � Septic tank and risers (water tight, insutated, proper depth, existing verified by pumping} <br /> mfg 150Q gallons none <br /> Riser over outtet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br /> No effluent fSlter 8 alarm <br /> Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> mfQ 1000 gallons <br /> � dase pump 47 gpm 14 head VERIFY PtJMP CURVE 4.1 min ON 9 hr OFF <br /> float setting drop 8.8 inches at 22.0 gpi "DESIGNED" 5.4 inches a <br /> � pprox float tether length <br /> 194.0 gal dose divided by gpi "INSTALIED" = inches float drop (field carrected <br /> LABEL pump requtrements and drawdown on riser or panel <br /> Cam lock reachable from grade - 30"max. J-hook weep hole. Suppty line access {no hard 90's) <br /> 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 steeve or compacted, and buried 6"+. <br /> sptice box/ control panet / electrical connections <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> mound absorption area rough up <br /> mound rock dimensions 10.0 X 6�.5 <br /> Sand lift depth 22 inches. (Jar test : 2"sand leaves < 1/8"silt after 30 min) <br /> � Absorption Sand beyand rock 0.0 upslope 17.0 downstope <br /> � Bermed topsoil beyond rockbed 11 upslape 15 sideslope z1 downs€ope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterals (1-2'from edge of rockj <br /> 2.OQ inch pipe size (Sch40 pipe 8 fittings) <br /> 3.0 ft laterai spacing <br /> e 1/4" inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system -if necessary �Re-use existing tank certification <br /> monitoring plan and type <br /> weli abandonment form - if necessary <br /> � <br /> � <br /> I <br /> � <br /> I <br /> I <br /> ! <br /> I <br /> � <br /> I <br /> I <br /> i <br /> � <br /> � <br /> ; <br /> � <br /> i <br /> � <br /> • , ; <br />