My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
fire code inspections
Orono
>
Property Files
>
Street Address
>
D
>
Dunwoody Avenue
>
2420 Dunwoody Avenue - 20-117-23-21-0018
>
Misc
>
fire code inspections
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:51:49 PM
Creation date
7/7/2016 1:12:03 PM
Metadata
Fields
Template:
x Address Old
House Number
2420
Street Name
Dunwoody
Street Type
Avenue
Address
2420 Dunwoody Avenue
Document Type
Misc
PIN
2011723210018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUMMIT FIRE PROTECTION <br /> 575 Minnehaha Ave.W • St. Paul,MN 55103 • 651-251-1880 3026 40T"Ave.NW • Rochester,MN 55901 • 507-280-0622 <br /> 418 Great Oak Dr. • Waite Park,MN 56387 • 320-257-6390 760 Liberty Way • North Liberty,IA 52317 • 319-665-4330 <br /> 4208 Enterprise Circle • Duluth,MN 55811 • 218-740-4412 4353 NW Urbandale Dr. • Urbandale,IA 50322 • 515-867-2424 <br /> SHEET t OF 2-Use separate sheet for each building inspection REPORT OF INSPECTION ,. _ <br /> . ;;.,,, - <br /> MINNESOTA LICENSE NO.C0075/IOWA LICENSE NO. FP-036 JOB NUMBER � `� — <br /> INSPECTION NAME :.-- �; �u{ � BUILDING/LOCATION <br /> STREET :�— ��l:r '� P-..,%<, �, . •,:�:_� � `�. INSPECTOR � ;1;�„; ,�J�j�G.� <br /> CITY&STATE ' :' -`r� � * -- :f' DATE %�� > t j;i <br />� . - _ <br /> Owner's Section(to be answered by Owner or Occ�pant) <br /> A. Explain any occupancy hazard changes since the previous inspection: <br /> B. Describe fire protection modifications made since last inspection: <br /> C. Describe any fires since last inspection: <br />� D. When was the system piping last checked for stoppage,corrosion of fareign material? <br /> E. When was the dry-piping system last checked for proper pitch? <br /> F. Are dry valves adequately protected from freezing? <br /> Signature Title Date <br /> Inspector's Section(All responses reference current inspection) NA=NOT APPLICABLE <br /> 1. General <br /> a.Is the building occupied?��Yes ❑No <br /> b.Are all systems in service? �1'es 0 No <br /> a Is there a minimum of 18 in.(457 mm)clearance between the top of the storage and the sprinkler de�flectors? �1'es ❑No <br /> d.Does the hand hose or standpipe on the sprinkler system(s)appear to be satisfactory? ❑Yes ❑No�NA <br /> 2. Control Valves(See ltem I5.) r...,�� <br /> a.Are all sprinkler system control valves and a11 other valves in the appropriate open or closed osition? �i-Yes ❑No <br /> b.Are all control valves in the open position locked,sealed or equipped with a tamper switch?�Yes❑No <br /> 3. Tanks,Pumps,Fire Department Connections �S <br /> a.When was fire pump last tested for performance? ��Y <br /> b.Are fire pumps,gravity tanks,reservoirs and pressure tanks in good condition and properly maintained? ❑Yes 0�10�NA <br /> c.Are fire department connections in satisfactory condition,couplings free,caps in place,and check valves tight? 67`Xes ❑No ❑NA <br /> Are they accessible and visible?'�Yes❑No ❑NA <br /> 4. Wet Systems p <br /> a. Have antifreeze system solu�ions�en tested? ❑Yes ❑No C�1"NA <br /> b.What temp is antifreeze? '✓,t <br />� � c. In areas protected by wet system(s),does the building appear to be properly heated in all areas? ❑Yes ❑No�1A <br /> 5. Dry System(See Items 11 to 13� <br /> a.Are dry valve(s)in service? Yes ❑No ❑NA <br /> b.Are the air pressures and priming water levels in accordance with the manufacturer's instructions? l�'es No❑NA <br /> c.Has the operation of the air or nitrogen supplies been tested? �es 0 No ❑NA Are tt�ey in service? �'es 0 No ❑NA <br /> d.Were low points drained during this inspection?�Yes ❑No NA How many? p` <br /> e.Did quick-opening devices operate satisfactorily? �Yes ❑No J�NA <br /> � f.Did the dry valve(s)trip properly during the trip pressure test?�Yes ❑No 0 NA <br /> �I g.Did the heating equipment in the dry-pipe valve room(s)operate at time of inspection?,�'es ❑No ❑NA <br /> 6. Special Systems(See Item 14.) <br /> a.Did the deluge or pre-action vaLves operate properly during testing? ❑Yes 0 No ❑NA <br /> b.Did the heat-responsive devices operate�pkroper}y during testing? ❑Yes ❑No ONA <br /> c.Did supervisory devices operate during,testing? �Yes❑ No ❑NA <br /> d.Did flow for kitchen hood systetri shut off g�"s or electric? ❑Yes 0 No ❑NA <br /> 7. Alarms <br /> a.Did water motor(s)and gong(s)test satisfa�torily? ❑Yes ❑No C�NA <br /> , <br /> b.Did electric alarm(s)test satisfactorily? �Yes 0 Ng ❑NA *' f f;,,; a�y,:",•. f <br /> c.Did supervisory alarm service test satisfactorily? G1�Yes ❑No a�IA �;',,;, .� . r •� °�-� ' -�'=' <br /> d.Did tamper switches test satisfactorily? �Yes ❑No❑NA ��� ��'' ���; `� ` � � � � <br /> 8. Sprinklers <br /> a.Are all sprinklers free from corrosion,paint,loading or obstruction to spray discharge? �Yes ❑No <br /> b.Are sprinklers less than 50 years old?(Older sprinklers require sample testing) CfYes ❑No <br /> c.Are quick response and residential sprinklers less than 20 years old?(Older sprinklers require sample testing) �Yes ❑No ❑NA <br /> d.Is stock of spare sprinklers available? ❑Yes �No <br /> e.Does the exterior condition of sprinkler system appear to be satisfactory? �lYes❑No <br /> f.Are sprinklers of proper temperature,�ating for their locations? �IYes❑No <br /> g.Is location free of recalled heads? �Yes ❑No <br />� <br /> . ' � <br /> � <br /> � <br /> Signature: � � _ Date: ���� �� � <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.