Laserfiche WebLink
PiLnvG �scx�w azvcxoxs> <br /> CONTRACTOR SHALL FURI�IISH ALL LABOR, EQUIPMENT, SERVICES AND <br /> PERFORM ALL OPERA.TIONS AS NECESSARY TO INSTALL PILING AT THE <br /> PROPER LOCATIONS TO TI-� PROPER DEPTH OR BEARING VALUES AS <br /> SHOWN ON THE DRAWING. PILING SHALL BE INSTALLED IN ACCORDANCE <br /> WITH ALL APPLICABLE BUILDING AND SAFETY CODES. <br /> PILE SHALL BE GALVANIZED SCREW ANCHOR DESIGNED AND INSTALLED <br /> ACCORDING TO STANDARD INDUSTRY PRACTICE. <br /> PILE CAPACITY <br /> PILE TO BE DESIGNED FOR WORKING LOAD SHOWN ON DRAWINGS W�TH A <br /> FACTOR OF SAFETY OF 2.0. A NIINIMUM OF 5 KIPS HAS BEEN RESERVED <br /> FOR DOWN DRAG ON THE PILE. <br /> ANCHORS SHALL HAVE SUFFICIENT STRL�IVGTH FOR THIS A1�1D SHALL <br /> WITHSTAND INSTALLATION LOADS. <br /> PILE <br /> PILES WHICH ARE DAI�IAGED, MISLOCATED, OR DRIVEN OUT OF <br /> ALIGNMENT SHALL BE ABANDONED. <br /> A TOLERANCE OF 3" FROM THE DESIGNED LOCATION SHALL BE <br /> PERMITTED IN THE INSTALLATION. <br /> 97228 <br /> C0""�10" N°� J. H. Dahlmeier <br /> RESIDENCE 972 $ <br /> �,►, � Engineering Inc. <br /> `405 DUNWO�DY JH S -� <br /> ❑f��N�, MN ct+E JH 2434 Commerce Boulevard 612-472-4746 11/3/97 <br /> Mound, MN 55364 Fax 612-472-4761 <br />