Laserfiche WebLink
� o� <br /> o..�:,` o <br /> -T����=� 4- CITY of ORONO <br /> 1 �'•���T? Y7 <br /> � ���'' �i r�--. ?�+,. <br /> `� 'y'��'�-��'f' �' hlunici OfTices <br /> � ��i;��,��j=�?���y G',► P� <br /> 1���;�;;;;-,Og�'y � Street Address: MailinQ Address: <br /> �'$II 2150 Kelley Parlcway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> 95d-�49-4600 <br /> To Current Owner: Address: �3� Q;�2�/ L`'�+ke ��'. <br /> Ciry Ordinance 199 requires fhat each existin�on-site sewa?e treatment system in Orono be inspected every two years. <br /> The on-site sewa�e treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CO�tFORI�IITY (1-3): � <br /> lO "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An tSTS which does not mect all the location,design and construction standards of the current Orono biunicipal <br /> Code but does meet the three foot seParation requirement or two foot requirement for systcros installed 1996 or earlier,and which is not failino or <br /> an immincat thrcat to public health or safety. <br /> 3 "NON-COi�IPLIANT SYSTENi" A prohibited ISTS;an iSTS located within a designated l00-year flood plain,any ISTS which may <br /> or may not mect all the location,design,ar conswction standards of t�e curnnt Orono Municipal Codc and which is failing for any reason;and <br /> any ISTS with less than tivice fcet of unsaturatcd soil or sand betwecn the distribution device and the limiting soi]chazacteristiu. <br /> TANK CONDITION(5-.7�: 5 <br /> Tank inspection indicates: <br /> �Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (ciry code requires tanks to be pumped out once every 3 years. <br /> �` Tank was last pumped S- �3�0� 1. <br /> Nlake sure septic tanks are pumped throuah manhole and not through white insuection pipes <br /> This allo�vs for the proaer cleanin�. <br /> 7 Inspection risers missin�tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. <br /> DR4I�IFIELD CONDITION(S3-1Q): �� <br /> � Dninfield is dry,no surfacin'evident. <br /> 9 Some evidence of surfacin�,not critical yet. <br /> 10 Drainfieid is saturated and visibly dischar�in�untreated effluent to the surface. Contact the Ciry Inspector � <br /> immediately.Repairs must be completed within 90 days. <br /> CONII�NTS: r"o�'^� �^� S�P�-:� ��IcS (ock OK - <br /> -7—\6 -d�- �� ��2�2�.,,� <br /> Date of Inspection bfatt Bolterman- Septic System Inspector <br /> Note: In the event that this inspcction report is used to satisfy the tequircmenes for a mortgage or other transfer of propetty,be adviscd that this repoR does not guarant�e <br /> or certify that an eristina systcm will continue to function propedy,but is merely an opinion ofthe adequacy of the system under current conditioru based on the availabie <br /> information. <br />