Laserfiche WebLink
_—� <br /> ,-_ �� <br /> ;;� � 0.�.\ <br /> � <br /> 0 O <br /> �; : � �I�Y of ORONO <br /> � , � <br /> �� � �� � ��� � � , <br /> �'' ;y " � Municipal Offices <br /> � , ;, <br /> ��� �� '� 1<�'�G�;�� Street Address �15a-a�}9-y6o o Mailing Address: <br /> `9kEggOg' 2750 Kelley Parkway P.O. Boz 66 <br /> ----� Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ��`� U •�e� ��'�� ��- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY 1-3 : � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does noi meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or eazlier,and <br /> which is not failing or an imm;nent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the luniting soi]characteristics. <br /> TANT�CONDITION(5-7): �� <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �'Z� '>� ). <br /> Make sure septic tanks are pumped through manhole and not throu�h white inspection pipes. This allows for the proper <br /> cleanine. Keep water softner and iron filter discharee out of septic system to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still workin�in your house. The alarm warns owner that septa�e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could riot be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : <br /> 8 rainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacin�,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: /�'`G ,���,( d-- S e�? �--� ��,�.'�5 `b�K ��_ <br /> --7 —� —o� uti�-,�� � , y <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />