Laserfiche WebLink
. , �-��O <br /> C ITY OF ORONO <br /> ,a � Street Address: Mailing Address: Telephone(952)249-4600 <br /> �' Gti 2750 Kelley Parkway P.O. Box bb Fax (952)249-4616 <br /> F <br /> �,9 �, Orono, MN 55356 Crystal Bay, MN 55323 www.ci.orono.mn.us <br /> kESHOR <br /> May 18, 2016 <br /> Rob Peterson <br /> Robert Craig Homes, Inc. <br /> 464 2"d Street, Suite 101 <br /> Excelsior, MN 55331 <br /> Re: Building Permit Application#2016-00486 <br /> 1885 Concordia Street <br /> On May 6, 2016 the City received a building permit application for a new single family home. We conducted a <br /> preliminarjr review based fln the informa#ion provided and recommend the foilowing items be submitted or revised in <br /> order for your application to be considered complete and for the plan review to continue: <br /> 1. Certificate of Survey. A survey dated 4/28/2016 was submitted with the application. Additional information <br /> is required. Please provide two copies of an updated,full-size certificate of survey which meets all of the City's <br /> survey standards (enclosed) indicating the following: <br /> a. Provide the bluff analysis data, cross sections, and show cross section location(s)on survey. <br /> b. Show the limits of the bluff impact zone. <br /> c. The scale of the survey is incorrectly noted as 1"=40', it should be 1"=20'; please correct. <br /> d. There are lines and other features used on the survey which are not identified in the key. Please have <br /> all features clearly identified. <br /> e. The top of foundation elevation is shown on the survey. Please have the surveyor show the point or <br /> spot where the top of foundation elevation is in reference to. Please note,we expect the location to <br /> be consistent when submitting the foundation as-built survey. <br /> f. Please identify the source for the topography overlay shown. <br /> g. It appears the northwest retaining wall exceeds 4 feet in height. Walls greater than 4 feet in height <br /> must be designed by a licensed professional,and plans must be submitted to the City for review prior <br /> to the approval of the permit. Tiered walls are considered one wall unless they are separated by at <br /> least twice the height of the lower wall. <br /> h. Special care will need to be exercised in creating the drainage pattern on the eastern side of the <br /> property to ensure that run off is not directed onto the neighboring property. <br /> i. A construction entrance should be provided to the site to ensure soil is not tracked onto the road. <br /> Perimeter erosion control measures should be installed by the Contractor and inspected by the City <br /> prior to any work.Contractor must provide minimum 24 hour notice prior to inspection <br /> 2. Landscape Plan. A landscape plan was submitted. Please provide clarification on the following: <br /> a. The existing stairs to lake are shown. Will this stair system be used or will the stairs be re-built? <br /> b. A pool is shown on the landscape plan. Pool plans were not submitted with the application. Is the <br /> pool to be constructed now or at a later date? <br /> 3. HardcoverCalculations. The property is located in Tier 1 of the Stormwater Quality Overlay District. Hardcover <br /> calculations are shown on page A1 of the architectural plans. Please have the surveyor prepare hardcover <br /> calculations, showing existing and proposed hardcover using the City's Hardcover Calculation Worksheet. <br /> Enclosed is a copy of the City's Hardcover Information Packet. <br />