# • ' ' � <br /> - -- ---- <br /> Rhvac Residential 8 Light Commercial HVAC Loads Elite Software���ent,Inc� <br /> Upper Midwest Radiant '� KQnb Mueller <br /> Maple Plain, MN 55359 � Page 4 <br /> Total Building Summary Loads <br /> Component Area Sen Lat Sen Totall <br /> Description Quan Loss Gain Gain Gain ', <br /> - _ _ _ _ __ <br /> 3A-w-o: Glazing-Double pane low-e (e = 0.40), operable 290 12,910 0 15,597 15,597 <br /> window, wood frame, u-value 0.53, SHGC 0.61 <br /> 3A-w-o: Glazing-Double pane low-e (e = 0.40), operable 867 25,489 0 45,460 45,460 <br /> window, wood frame, u-value 0.35, SHGC 0.61 <br /> 15611-Ow-8: Wall-Basement, , framing with R-11 sill to 1041 4,878 0 107 107 <br /> floor in 2 x 4 cavity, core, no board insulation, plus <br /> interior finish, wood studs, 8'floor depth <br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 5052 28,858 0 5,632 5,632 <br /> cavity, no board insulation, siding finish, wood studs <br /> 166-44: Roof/Ceiling-Under Attic with Insulation on Attic 3458 6,391 0 3,727 3,727 <br /> Floor(also use for Knee Walis and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shinales �r Dark Metal, Tar and Gravel or <br /> Membrane, R-44 insulation <br /> 21A-32: Floor-Basement, Concrete slab, any thickness, 2 3458 5,809 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 32'wide <br /> Subtotals for structure: 84,335 0 70,523 70,523 <br /> People: 4 800 920 1,720 <br /> Equipment: 1,600 1,450 3,050 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 217, Summer CFM: 114 19,441 2,525 1,706 4,231 <br /> Ventilation: Winter CFM: 112, Summer CFM: 112 2,510 2,479 418 2,897 <br /> AED Excursion: 0 0 13,601 13,601 <br /> Humidification (Winter) 19.84 gal/day : 7,275 0 0 0 <br /> Total Building Load Totals: 113,561 7,404 88,618 96,022 <br /> __ _ _ - _ - - <br /> Check Figures _ __ . _ J <br /> -- - -- _ - - _____ -- -__-- -__ _ _-- --- <br /> Total Building Supply CFM: 3,306 CFM Per Square ft.: 0.399 <br /> Square ft. of Room Area: 8,281 Square ft. Per Ton: 841 <br /> Volume (ft') of Cond. Space: 81,445 <br /> Building Loads ' ' <br /> Total Heating Required Including Ventilation Air: 113,561 Btuh 113.561 MBH <br /> Total Sensible Gain: 88,618 Btuh 92 % <br /> Total Latent Gain: 7,404 Btuh 8 % <br /> Total Cooling Required Including Ventilation Air: 96,022 Btuh 8.00 Tons (Basea Un Sensible+ Latent) <br /> 9.55 Tons (Based On 75% Sensible <br /> Capacity) <br /> _ _ _._ _ __ _ __ _. _ _ <br /> Notes <br /> __ __- ------._ ___ _ _ __ <br /> Calculations are based on 8th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> ' � <br /> G:\UMR\Elite load calcs\Muler.rhv Thursday, October 29, 2009, 7:20 AM <br />