Laserfiche WebLink
� °� , <br /> � o � <br /> � o � �� <br /> � C ITY of ORONO <br /> I ,,�� ;; <br /> �\ � 4 ��,• _ � <br /> 1�� � <br /> `'� z�ti 'Jk� .- �C,� Municipal Oftices <br /> '�+� ��,M�r r�,� (, '�,; <br /> �����,t ��'4 @ 3�ta,�i �~: (J,ij% <br /> ,.,\\� ; ,'. ��¢ , Street Address: �15a-a4q'�6o � Mailing Address: <br /> ��' 2750 Kelley Parkway P.O. Box 66 <br /> `��g�%�,., <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: � �c�`= �' l�c`� �-�1 �--� �r - <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and consiruction standards of the current Orono <br /> Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent tlueat to public health or safery. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is faIling for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics. <br /> 1' <br /> TANK CONDITION(5-7): �_ <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ( l��l� ). <br /> Make sure septic tanks are pumped throu�h manhole and not through white inspection pipes. This allows for the proper <br /> cleaninE• Keep water softner and iron filter discharEe out of septic sYstem to prolong life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still working in vour house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> , <br /> ,� ,�`'� �� C� �� �,I �.� <br /> Date of Inspection ' Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not suarantee or certifi� that an existine svstem will continue to function properly, but is merelv an opinion of the adequacy of the svstem under current <br />