Laserfiche WebLink
,� °� <br /> �i <br /> ,, o o \ <br /> I, ,,,., rY:;�_ �; CITY of ORUNO <br /> ,� , �� � <br /> 1�� '�r': � +' � �C, �� Municipal Offices <br /> ��� z J�r �� j � ,� <br /> t � <br /> '`�� �'I��� ��,�`�_��r���-� G� Street Address: q Sa'a�q'�"16� � Mailing Address: <br /> �'���`9 '`�� '�'��'� 2750 Kelley Parkway P.O. Box 66 <br /> �����'ESI��,,%�' <br /> ���-�' Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Cunent Owner: Address: =�J I � � �' '3�-� �A �-� �('. <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and conshvction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an inuninent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS]ocated within a designated 100-yeaz flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped 1 �I �� �� ). <br /> Make sure septic tanks are pumped throush manhole and not through white inspection pipes. This allows for the proper <br /> cleaninE Keep water softner and iron filter discharee out of septic svstem to prolong life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still working in Vour house. The alarm warns owner that septa�e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: D rL! .'n ��e � D 1�,�i��'S C�x /�S��l %b S� ��l��'c� G � <br /> -%L1, C� �sTJ v n c� � f� j�i�2��' 'i �n Nl�tic� S,"G.�1 S C�� �'�A :�/u�� �� <br /> l�/� S t f /�/�� S� C'O n T A c�T /vt P_ A � G��-,� `/l - ��.76 <br /> "JO �f` � G :� s.S �i�.C� �o ( G'✓�c S. <br /> � - � `� _ O � (� ," � 1 '�� ��'13�3.� <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that ihis report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br />