2012-00802 - septic
Orono
>
Property Files
>
Street Address
>
D
>
Deborah Drive
>
420 Deborah Drive - 31-118-23-23-0009
>
Septic
>
2012-00802 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:30:06 PM
Creation date
6/15/2016 10:44:01 AM
Metadata
Fields
Template:
x Address Old
House Number
420
Street Name
Deborah
Street Type
Drive
Address
420 Deborah Drive
Document Type
Septic
PIN
3111823230009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
All tanks that have less than twa feet of cover shall have the lids insulated. <br /> Cleanouts shall be instalied at each lateral pipe in the mound. They shali he instatled in <br /> such a way as to have access to the surface and protected from damage, such as an <br /> irrigation box. <br /> The entire area that is to be used for the drainfield shall be protected from any traffic to <br /> prevent any compaction prior to and during construction. Failt3re to do so shall result in <br /> this design becoming VOID. At that time the site may have ta be tested again or an <br /> aiternate site located and testing done. <br /> All neighboring wells are located greater than 1Q0 fee#from the proposed drainfield site. <br /> The existing tank must be abandoned because it is to close to the well. <br /> Additives of any kind must not be used along with any chlorine or antibacterial solutions. <br /> They may cause damage to the system. <br /> Water softeners must be diverted vut vf the system this will prolong the life, and protect <br /> the concrete component of the system <br /> We recommend that there be no traffic Qf any kind an the mound area especially in the <br /> winter time as it may cause freezing. <br /> It is recommended to pump and service the septic tanks every two to three years for <br /> maximum life of the system. <br /> All requirements of this design must be fallowed in order for the system to perform to the <br /> design capabilities and for this design to be valid. <br /> This design is in compliance with local codes and Minnesota Pollution Control Chapter <br /> 7080 as of the date listed above. <br /> Respectfully <br /> Bob Volkenant <br /> MPCA Li�ense#Sb <br />