Laserfiche WebLink
. <br /> � � . . • . <br /> 3I0.9.i Smolce detectors. <br /> 310.9.I.I General.l�we7ling units,�congxegate residences and hotel or Iodging house guest . <br /> rooms that are used for sleepi.ng purposes shall be provided with smolce decectors:Detectors shall be <br /> installed in accord.ance tivi.th the approved manufacturex's i.nstructions. � <br /> 310.9.1.2 Additions, alterations or repairs to Group R Occupancies.VYhen the valuation of an <br /> additzon,al.teration or xepaix to a Group R Occupancy exceeds �1,000 and a permit is xequired, or <br /> tiyhen oneor moxe sleeping rooms are added�or exeated in existing Group R Occupancies, smoke <br /> detectorsshall be installed in accordance�vith Sections 3I0.9.I.3, 3I0.9.]..4 and 3I0.9.I.5 of this <br /> sec#ion. <br /> �XCEP'�'70N: Repairs�to the exterior surfaces of a Group R�Occupancy are exempt from the require- <br /> znents of thzs section. <br /> 310.9.1.3 Po�ver source. xn new construction, requixed smolce detectozs shall receive their pzi- <br /> mary pozver from the build.ing wiring when such wising is sezved from a corrunercial source and <br /> shall be equipped with a battery bacl<up. The detector shall emit a signal when the batteries are Io�v. <br /> tiYiri.ng shall be permanent and�irxthout a disconnecting stivitch other than those required for ovez- <br /> current protection. Sznolce detectors may be solely battery operated when i.nstalled in existing <br /> build.ings; or i.n bui.Idangs�vi�thout comznercial potiver; or in buildings tivhich undergo alterations, <br /> ,repairs or additions xegulated by Section 310.9.J..2. <br /> 3I0.9.1.4 X.ocation tivithi�n dwelling unzts. xn dwel.ling uni�ts, a detector sha1T�be installed in each <br /> sleeping room and at a point centrally located in the corridoz or area givixig access to each separate <br /> sleeping area. When the dwelling uzut has moze than one stoxy and in d�vellings with basements, a <br /> deiector shall be i.nstal.led on each story and in the basement. 7si dtivelling uzuts�vhere a story or base- <br /> ment xs spI.it i.nto two or m.ore levels, the smolce detector shall be izista7J.ed on the upper Ievel, except <br /> that tivhen the�otivez l.evel coz�tains a sleeping area, a detector sha1J,be znstal.T�ed on each Ievel.VYhen <br /> sleeping xooms are on an upper level, the detector shall be placed at the ceiling of the upper�evel in <br /> close proximzty to the staiz-tivay. xn d«relling uruts tivhere the ceiling height of a zoom operi to the <br /> hal.hvay servi.zig the bedrooms exceeds that of the hallway by 24 i.z�ches (6I.0 mm) or xnore, smoke <br /> detectors shall be installed in the halltivay and in the adjacent room. X?etectors shall sound an alarm <br /> audible in all sleeping areas of the dtivelling unit i�n whzch they are located. <br />