My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
05/19/03 Planning Commission Minutes
Orono
>
Planning Commission
>
2003
>
05/19/03 Planning Commission Minutes
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2012 3:47:01 PM
Creation date
2/27/2012 3:47:01 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MINUTES OF THE <br /> ORONO PLANNING COMMISSION MEETING <br /> Monday, May 19, 2003 <br /> 6:00 o'clock p.m. <br /> (#11 #03-2901 DENALI CUSTOM HOMES,INC. ON BEHALF OF MELINDA LEE <br /> AND THOMAS DEVEAU, Continued) <br /> Gaffron indicated that the applicants proposed to remove an existing house and construct a <br /> new house on the property located at 680 Tonkawa Road. The lot is located in the LR-1B <br /> zoning district requiring a minimum lot size of one acre and a lot width of 140'measured at <br /> the lakeshore and at the 75' setback. They are requesting variances to permit new <br /> construction on an undersized lot (0.54 acre)having a lot width of 64'. Also requested is a <br /> hardcover variance for the 75-250' zone to allow 29.15%where only 25% is normally <br /> allowed. <br /> Gaffron explained that the lot currently contains an existing residence structure which the <br /> owner wishes to replace. The site has steep slopes, and although a formal bluff analysis <br /> has not been done, the 0-75' zone appears to likely meet the criteria for a bluff. However, <br /> both the existing and proposed homes are outside of the bluff impact zone, and no work <br /> within the bluff impact zone is currently proposed. He noted that existing retaining walls <br /> and stairways in the 0-75' zone are in good condition and no changes are proposed. <br /> The proposed hardcover in the 75-250'zone is 3,311 s.f. or 29.15%. The proposed house <br /> plan indicates a 4'x14' deck on the lakeside of the house. The house is up against the 10' <br /> side setback on both sides. Gaffron pointed out that another way to reduce hardcover <br /> would be to re-orient the garage to be end loading, with a narrow driveway extending to <br /> the 250' line, then construct a backup apron and perhaps even an additional detached <br /> garage in the 75-250' zone where hardcover is available. This would require re-design of <br /> the home, and applicant has stated an end-load garage would not provide the entrance view <br /> of the home he is hoping to achieve by side-loading. However,with the same footprint as <br /> currently proposed, a savings of about 200 s.f. (1.8%) of hardcover could be realized. <br /> Gaffron pointed out that the City Engineer's inspection revealed serious concerns with the <br /> proposed grading plan which need to be resolved before this application would move <br /> forward. He shared three issues for consideration and indicated that staff would <br /> recommend: <br /> •Approval of the variances for lot area and lot width based on the fact the lot is <br /> developed as a single family dwelling, has been provided sanitary sewer service <br /> and it would not be possible to acquire additional land to create a conforming lot. <br /> •Denial of the hardcover variance for hardcover in excess of 25% in the 75-250' <br /> zone, based on the fact that a house could be constructed on the property meeting <br /> the 25% limit. <br /> •Tabling of the application for revisions to meet the 25% limit, and for submittal <br /> of a revised grading and drainage plan addressing the concerns of the City <br /> Engineer. <br /> PAGE 34 of 39 <br />
The URL can be used to link to this page
Your browser does not support the video tag.