Laserfiche WebLink
SECTION R310 <br /> EMERGENCY ESCAPE AND RESCUE OPENINGS R310.2 Window wells. The minimum horizontal area of the <br /> R310.1 Emergency escape and rescue required.Basements Window well shall be 9 square feet (0.9 mz), with a minimum <br /> and every sleeping room shall have at least one operable emer- " horizontal projection and width of 36 inches (914 mm). The <br /> gency escape and rescue opening. Such opening shall open az'ea of the window well shall allow the emer=ency escape and <br /> directly into a public street,public alley,yard or court.Where rescue opening to be fully opened. <br /> basements contain one or more sleeping rooms, emerQency Exception:The ladder or steps required by Secrion R310.2.1 <br /> egress and rescue openings shall be required in each sieepin� shall be pernutted to encroach a maximum of 6 inches (152 <br /> room,but shall not be required in adjoinin� areas of the base- mm)into the required dimensions of the window well. <br /> ment. Where emer�ency escape and rescue openinas are pro- R310.2.1 Ladder and steps.Window wells with a vertical <br /> vided they shall have a sill height of not more than 44 inches depth greater than 44 inches(1118 mm) shall be equipped <br /> (1118 mm) above the floor. Where a door opening having a �,ith a permanently affixed ladder or steps usable with the <br /> threshold helow the adjacent �round elevation serves as an �,indow in the fully open position.Ladders or steps required <br /> emergency escape and rescue openin� and is provided with a by this section shall not be required to comply with Sections <br /> bulkhead enclosure,the bulkhead enclosure shall comply with R311.5 and R311.6. Ladders or runcs shali have an inside <br /> Section R310.3.The net clear opening dimensions required by �,,,�dth of at least 12 inches(305 mm),shall project at least 3 <br /> this section shall be obtained by the normal operation of the inches(76 mm)from the wall and shall be spaced not more <br /> emergency escape and rescue openin� from the inside.Emer- �an 18 inches (457 mm) on center vertically for the full <br /> gency escape and rescue openings with a finished sill height height of the window well. <br /> below the adjacent ground elevation shall be provided with a <br /> window well in accordance with Section R3102. Emergency R310.3 Bulkhead enclosures. Bulkhead enclosures shal] pro- <br /> escape and rescue openings shall open directly into a public vide direct access to the basement.The bulkhead enclosure with <br /> way, or to a yard or court that opens to a public way. the door panels in the fully open position shall provide the mini- <br /> Exception: Basements used only to house mechanical mum net clear opening required by Section R310.1.1.Bulkhead <br /> equipment and not exceeding total floor area of 200 square enclosures shall also comply with Section R311.5.8.2. <br /> ' feet(18.58 mz). R310.4 Bars, grilles,covers and screens. Bars, grilles, cov- <br /> R310.1.1 Minimum opening area. All emergency escape ers, screens or similar devices are permitted to be placed over <br /> and rescue openinDs shall have a minimum net clear open- emergency escape and rescue openings,bulkhead enclosures, <br /> ing of 5.7 square feet(0.530 m2). or window welis that serve such openings, provided the mini- <br /> mum net clear opening size complies with Sections R310.1.1 <br /> Exception: Grade floor openings shall have a minimum to R3l 0.1.3,and such devices shall be releasable or removable <br /> net clear opening of 5 square feet(0.465 mz). from the inside without the use of a key, tool, special knowl- <br /> R310.1.2 Minimum opening height. The minimum net edge or force greater than that which is required for normal <br /> clear opening height shall be 24 inches (610 mm). operation of the escape and rescue opening. <br /> R310.1.3 Minimum opening width. The minimum net R310.5 Emergenc3� escape windows under decks and <br /> clear opening width shall be 20 inches (�08 mm). porches. Emergency escape windows are allowed to be <br /> installed under decks and porches provided the]ocation of the <br /> R310.1.4 Operational constraints.Emer�ency escape and deck allows the emerQency escape windov✓to be fully opened <br /> rescue openings shall be operational from the inside of the and provides a path not less than 36 inches (914 mm)in height <br /> room without the use of keys,tools or special knowledge. to a yard or court. <br />