<br /> Component Area Sen. Lat. Sen. Total
<br /> Description Quan Loss Gain Gain Gain
<br /> 4A Window Double Pane & Storm Clear Glass Wood Frame 514 16,125 0 15,000 15,OOC
<br /> 8M Glass Door pouble Clear Glass Wood Frame 74 3,752 0 2,220 2,220
<br /> 11 C Door Metal Polystyrene Core 38 1,643 0 422 422
<br /> 121 Wall R-19 + 1/2'° Asphlt Board(R-1.3) 3,012 15,241 0 3,910 3,910
<br /> 15F Wail 5' or More Below Grade 8/12" BIk+R-5 1,290 7,001 0 0 0
<br /> 161 Ceiling R-44 Insulation 1,668 3,530 0 1,688 1,688
<br /> 21 A Basemt Floor 2' or More Below Grade 1,668 3 683 0 0 0
<br /> Subtotals for structure: 8,264 50,975 0 23,240 23,240
<br /> Active People: 6 0 1,380 1,800 3,180
<br /> Inactive People: 0 0 0 0 0
<br /> Appiiances: u G 30u 1,2u0 i,500
<br /> Lighting: 0 0 0
<br /> Ductwork: 0 0 0 0 0
<br /> Infiltration: Winter CFM: 230.8, Summer CFM: 153.9 626 23,357 3,766 3,385 7,151
<br /> Ventilation: Winter CFM: 125.0, Summer CFM: 125.0 0 12 650 3 059 2 750 5 809
<br /> Sensible Gain Total: 32,375
<br /> Temperature Swinq Multiplier: X1 00
<br /> Buildinq Load Totals: 86,982 8.505 32 375 40 880
<br /> ----- ........
<br /> �h�k�k �r�s.
<br /> ;::>::>:: :.
<br /> _� ;:,>;;:;;. .::::
<br /> Total Building Supply CFM: 1347 CFM per square foot: 0.273
<br /> Square feet of room area: 4,936 Square feet per ton: 1,372.17
<br /> ;.�.;.:::>�"<::::>::;;:';::;::::>::.:>�_:`:::��'>::::::::�:>:::�::»'>:'::<:>::::::::>::>::`;::::>:�::>::»::s<<`::�:`:`>:'`::''::::::::<:;::::<'»»:<:`;::;�>_::;<`::::�:::::;::`�:�:::'>:::�:�:<'':'':<::<:::::::>':::<>:::':::::;::::::>:�:;:<::::«<::::::::::>::::::::::>:�::<::::::<:':::;:>:::<:<::::>::::::::::::::>::>':>':�:::>;':>::;:::>':;::::::::<:>:::'>::;`::::>::::::::::::::::::`:>:':::::�::<::::<::::;:::::::':;:;::::�:
<br /> u��...��x�.�.��#�.:::.;:.:::.;::::<.;:..;.;:.;.:;:.;:.;.;:.;:::::..::: :::::.:.::.>:.;:.::.;:.;:.;;:.;:.;;:.. .... ... ..........
<br /> Total heating required with outside air: 86,982 Btuh 86.982 MBH
<br /> Total sensible gain: 32,375 Btuh 79 %
<br /> Total latent gain: 8,505 Btuh 21 %
<br /> Total cooling required with outside air: 40,880 Btuh 3.407 Tons (based on sensible + latent)
<br /> 3.597 Tons (based on 75% sensible capacity)
<br /> ��#�� ' '� '
<br /> ; , ; ;
<br /> ;,
<br /> :
<br /> _ , ; >
<br /> ; , �
<br /> Calculations are bas�d on 7th edition of ACCA Manual J.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads.