My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2002-P05242 - new septic
Orono
>
Property Files
>
Street Address
>
C
>
Crystal Creek Road
>
165 Crystal Creek Road - 33-118-23-33-0005
>
Septic
>
2002-P05242 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:49:59 PM
Creation date
6/7/2016 12:38:04 PM
Metadata
Fields
Template:
x Address Old
House Number
165
Street Name
Crystal Creek
Street Type
Road
Address
165 Crystal Creek Road
Document Type
Septic
PIN
3311823330005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
View images
View plain text
^�-7 l ���j <br /> ` V. <br /> � . <br /> , ' _ . � AJ � !A. �� J6. �L 1 � V' ���• <br /> � 951 KATYDID LANE <br /> � ST. MICHAEL, MN 55376 <br /> 497-3566 <br /> Steven �. SChirmers <br /> ( �,'�} C r _-! S�_� �� � ��r'� � �1 September 28 , 1989 <br /> +�/ <br /> Al1an Carlson <br /> Lot 4 , Block 1 i-- ��u,� <br /> Crystal Creek �- �S� <br /> Orono, Henn. Co. , MN <br /> � V <br /> This system is Designed for a Type 1, four bedroom home and in accordance <br /> with the Minnesota Pollution Control Agency Chapter 7080 and local <br /> ordinances . <br /> The soils on this site ar'e typical of SCS soils mapped - LrB - Lester <br /> loam & L+B - LeSueur loam. A seasonally high water table was located <br /> at 18" , 20" , 32" , 34" & 66" , (mottled soil ) . Due to the seasonally <br /> high water table, a pressurized mound system will need to be installed. <br /> The bottom of the rock bed must be located at least 3 ' above the <br /> seasonally high water table . <br /> The soils at a depth of 12" & 18" have a percolation rate averaging <br /> 8 . 5 min/inch and are adequate for treating septic effluent. <br /> A pumping chamber will need to be installed to lift the effluent to the <br /> treatment area. <br /> The manifold and supply line pipe must have back drainage to the pumping <br /> chamber . The distribution pipes shall have their ends capped. Be sure <br /> the rock and sand fill material are clean. The sod layer below the <br /> entire mounded area must be turned over, just break up the sod, be sure <br /> not to over work. <br /> The power supply and switches must be located outside the manhole and <br /> pumping chamber in a weather proo£ enclosure. A warning device must be <br /> installed with a light and sound device , this is in case of a pump failure . <br /> (Mercury floats are a good method) . <br /> Al1 neighboring wells are . located more than 100 ' away from the proposed <br /> treatment area . <br /> Keep all heavy equipment off of the proposed treatment area before and <br /> after construction a� much as possible . The treatment area should be <br /> marked off before construction. . <br /> . � � �-�� <br /> � 1 � : uv <br /> CONT ' D <br /> Soil ared Percolation :''eats <br /> Septic System Design <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).