CHARLES CUDD CO. <br /> � � � e.� - �. <br /> House Specifications <br /> Landscaping <br /> Front Yard $1000 Sod Allowance <br /> Side Yards <br /> Rear Yard <br /> Retaining Walls Per Lot, See Site Plan <br /> Entry Area <br /> Foundation <br /> Walls 8"Poured Wall w/ 12"at brick ledge-see elevations <br /> Footings Continuous poured <br /> Basement Slabs 3 U2"thick <br /> Garage Slab 4"thick w/wire mesh <br /> Crawl Space Slab 3 1/2"thick <br /> Basement Wall Height 8'-4" <br /> Lookout Wall Height 4'-0" <br /> Walkout Wall Height 4'-0" <br /> Waterproofing& 2"rigid insul R-10 with mastic and poly, protective coating where exposed <br /> Insulation <br /> Site <br /> Sidewalks 48"wide, see survey for layout <br /> Retaining Walls See Site plans <br /> Drop Siding on Foundation N/A <br /> Walls <br /> Curb Cuts See Site Plan <br /> Driveways 38' wide at garage for 3 stall-taper to 27' wide at curb, see survey <br /> General Construction <br /> Floor System Engineered I-joists <br /> Sheathings Roof 1/2"oriented strand board <br /> Wall 25/32"builtrite <br /> House Wrap _Tyvek or equivalent,where applicable <br /> Wall Framing Exterior 2x6 16"o/c,unless noted otherwise <br /> Interior 2x4 16"o/c,unless noted otherwise <br /> Plumbing 2x6 16"o/c,unless noted otherwise <br /> Bsmt Load Bearing 2x6 16"o/c,unless noted otherwise <br /> Bsmt Non-Load Bearing 2x4 16"o/c,unless noted otherwise <br /> Roof System Engineered Trusses <br /> Insulation Walls R-19 Friction Fit w/4 mil VB <br /> Roof R-44 Blown Fiberglass, Vaults-R-38 Batt w/4 mil VB <br /> Sound(Plumbing) R-11 Friction Fit <br /> Garage Warm Walls R-19 Friction Fit w/4 mil VB <br /> 10/14/99 2 <br />