My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
C
>
Cristofori Circle
>
45 Cristofori Circle - 31-118-23-43-0012
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:32:51 PM
Creation date
5/24/2016 10:41:50 AM
Metadata
Fields
Template:
x Address Old
House Number
45
Street Name
Cristofori
Street Type
Circle
Address
45 Cristofori Circle
Document Type
Septic
PIN
3111823430012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . <br /> J , � <br /> S-� �'�S�'dN�, _�1��'. <br /> 951 KATYDID LANE <br /> ST. MICHAE�, MN 55376 <br /> 497-3566 <br /> . Steven 3.. S�hirmers _. <br /> ' October 2, 1989 <br /> Dan Parten ' <br /> 4300 Bayside Rd. <br /> Existinq House <br /> Orono, Henn. Co. , MN <br /> This system is Designed for a �i�ype i, �our bedroom home and in accordance <br /> with the Minnesota Pollution Control Agency Chapter 7080 and local <br /> ordinances . <br /> The soils on this site are typical of SCS soils mapped - KIC2- Kilkenny <br /> clay loam. A seasonally hign water table was located at 12" , 14" & <br /> 20" , (mottled soil ) . This site has an existing pressurized mound system. <br /> The site was tested for future expansion for a Sub-Division. Due to the <br /> � seasonally high water table, the future expansion area will need to be <br /> a pressurized mound system. The bottom of the rock bed must be located <br /> at least 3 ' above the seasonally high water table. <br /> The soils at a depth of 12" have a percolation rate averaging 21. 1 <br /> min/inch and are adequate for treating septic effiuent. <br /> A pumping chamber will need to be instalied to lift �ne effluent to the <br /> treatment area. <br /> The manifold and supply l,ine pipe must have back drainage to the pumping <br /> chamber . The distribution pipes shall have their ends capped. Be sure <br /> the rock and sand fill material are clean. The sod layer below the <br /> entire mounded area must �be turned over, just break up the sod, be sure <br /> not to over work. <br /> The power supply and switches nust be locat�:� outside the manhole and <br /> pumping chamber in a weat,her proof enclosure. A warning device must be <br /> installed with a light and sound device , this is in case of a pump failure. <br /> (Mercury floats are a good method) . <br /> All neic�hboring wells are located more than 100 ' away. from the proposed <br /> treatment area . <br /> Keep all heavy equipment off of the proposed treatment area before and <br /> after construction as much as possible . The treatment area should be <br /> marked off bef ore construction. � <br /> ' CONT ' D <br /> Soi! and Percolation Tests <br /> Septic System Design <br />
The URL can be used to link to this page
Your browser does not support the video tag.