My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00289 - COO
Orono
>
Property Files
>
Street Address
>
C
>
Chippewa Lane
>
4220 Chippewa Lane - 31-118-23-42-0012
>
Permits/Inspections
>
2016-00289 - COO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:32:20 PM
Creation date
5/18/2016 3:22:20 PM
Metadata
Fields
Template:
x Address Old
House Number
4220
Street Name
Chippewa
Street Type
Lane
Address
4220 Chippewa Lane
Document Type
Permits/Inspections
PIN
3111823420012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� _ - -- _ -- _ - ___ _ - - - <br /> - _- <br /> I Rhvac-Residentiat&Light Commerciai HVAC Loads Elite Software Development,Inc. j <br /> West Metro Mechanical Inc. � M&M Orono Model Home <br /> i �Norwood.MN 55368 Pa e 10 <br /> ----- _- _ _ _ <br /> � Detailed Room Loads - Room 3 - Bath, Bed 3, Bed 2, Laundry, Bath (Average Load <br /> Procedure) <br /> General <br /> Calculation Mode: Htg. &clg. Occurrences: 1 <br /> Room Length: 39.0 ft. System Number: 1 <br /> Room Width: 19.0 ft. Zone Number: 1 <br /> �' Area: 741 A sq.ft. Supply Air: 232 CFM � <br /> Ceiling Height: 8.1 ft. Supply Air Changes: 2.3 AC/hr <br /> Volume: 5,989.5 cu.ft. Req. Vent. Clg: 0 CFM <br /> j Number of Registers: 3 Actual Winter Vent.: 28 CFM <br /> Runout Air: 77 CFM Percent of Supply.: 12 % <br /> Runout Duct Size: 5 in. Actual Summer Vent.: 35 CFM <br /> I Runout Air Velocity: 568 ft./min. Percent of Supply: 15 % <br /> Runout Air Velocity: 568 ft./min. Actual Winter Infil.: 26 CFM <br /> I Actual Loss: 0.259 in.wg./100 ft. Actual Summer Infil.: 14 CFM '� <br /> Item Area -U- Htg Sen Clg Lat Sen . <br /> I Descri tion Quantity Value HTM Loss HTM Gain Gain I <br /> ' N -Wall-12F-Osw 19 X 8.1 147.5 0.065 5.3 776 1.1 0 156 <br /> E-Wall-12F-Osw 39 X 8.1 239.5 0.065 5.3 1,261 1.1 0 254 I <br /> S-Wall-12F-Osw 19 X 8.1 153.6 0.065 5.3 809 1.1 0 163 <br /> N -Gis-1 F-hw-o shgc-0.3 100%S 6.1 0.440 35.6 218 12.8 0 78 'I <br /> E-Gls-1 F-hw-o shgc-0.3 0%S (4) 59.1 0.440 35.6 2,108 35.1 0 2,076 <br /> E-GIS-1 F-hw-O ShgC-0.3 0%S (2) 16.7 0.440 35.6 594 35.0 0 584 ' <br /> UP-Ceil-16B-60 39 X 19 __ _ _]41 0.020 _ _ 1.6 __ 1,200 __ _ 1.0 _ Q 756_ <br /> � Subtotals for Structure: 6,966 0 4,067 <br /> Infil.: Win.: 25.6, Sum.: 13.7 622 3.557 2,214 0.376 272 234 I <br /> AED Excursion: 427 <br /> People: 200 IaUper 230 seNper. 1 _ _ _ _ _ __ __ 200 230 <br /> Room Totals: 9,180 472 4,958 <br /> C:\...\M&M Orono Model Home.rh9 Sunday, March 20, 2016, 9:53 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.