Laserfiche WebLink
, _, _ _--- - - - - _ _ _ _ _ - -- - - - , <br /> ! Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. I <br /> II West Metro Mechanical Inc. � M&M Orono Model Home � <br /> Nonvood MN 55368 _ _ _ _ Page 6 <br /> � i TotalBuildinq Summary Loads <br /> iComponent Area Sen Lat Sen Total <br /> � Description Quan Loss Gain Gain Gain j <br /> i 1 F-hw-o: Glazing-Triple pane, operable window, heat- 659.1 23,494 0 20,410 20,410 I <br /> � absorbing, wood frame, u-value 0.44, SHGC 0.3 <br /> �I 1 F-hw-o: Glazing-Triple pane, operable window, heat- 14.8 33 0 33 33 <br /> j absorbing, wood frame, in partition wall, u-value 0.44, <br /> SHGC 0.3 <br /> 11D: Door-Wood- Solid Core 117 3,696 0 1,232 1,232 <br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 3981.6 20,963 0 4,219 4,219 <br /> cavity, no board insulation, siding finish, wood studs <br /> I 12F-Osw: Part-Frame, R-21 insulation in 2 x 6 stud cavity, 198.7 65 0 65 65 � <br /> no board insulation, siding finish, wood studs <br /> II 15B0-10sf-2: Wall-Basement, , R-10 board insulation to 1056 6,601 0 800 800 I'� <br /> I floor, no interior finish, 2'floor depth I <br /> I 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 2080 3,369 0 2,122 2,122 j <br /> I Floor(also use for Knee Walls and Partition I <br /> �i Ceilings), Vented Attic, No Radiant Barrier, Dark �I <br /> � Asphalt Shingles or Dark Metal, Tar and Gravel or I <br /> Membrane, R-50 insulation � <br /> II 21A-20: Floor-Basement, Concrete slab, any thickness, 2 1920.1 4,198 0 0 0 ; <br /> I or more feet below grade, no insulation below floor, � <br /> I __a_n�floor_cov_er shortest_side of floor slab is_20'wide_ __ ___ ___ _ .___._________ ______ i <br /> Subtotals for structure: 62,419 0 28,881 28,881 � <br /> j People: 4 800 920 1,720 � <br /> Equipment: 0 0 0 j <br /> Lighting: 0 0 0 <br /> I� Ductwork: 0 0 0 0 <br /> � Infiltration: Winter CFM: 237, Summer CFM: 127 20,448 2,508 2,164 4,672 <br /> i Ventilation: Winter CFM: 250, Summer CFM: 250 8,645 4,947 1,708 6,655 <br /> i Exhaust: Winter CFM: 250, Summer CFM: 250 <br /> j AED Excursion;_ _ _ __0 ____ 0 _ __3 011 ._ _ _ 3 011 <br /> I Total Building Load Totals: 91,512 8,255 36,683 44,938 <br /> Check Fi ures <br /> I Total Building Supply CFM: 1,639 CFM Per Square ft.: 0.296 <br /> Square ft. of Room Area: 5,539 Square ft. Per Ton: 1,479 <br /> Volume (ft3) of Cond. Space: 52,893 <br /> Building Loads <br /> I Total Heating Required Including Ventilation Air: 91,512 Btuh 91.512 MBH <br /> j Total Sensible Gain: 36,683 Btuh 82 % <br /> j Total Latent Gain: 8,255 Btuh 18 % <br /> I Total Cooling Required Including Ventilation Air: 44,938 Btuh 3.74 Tons(Based On Sensible + Latent) <br /> II Notes <br /> j Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. I <br /> All computed results are estimates as building use and weather may vary. i <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at ! <br /> your design conditions. ! <br /> i <br /> --- - --- - <br /> C:\ ...\M&M Orono Model Home.rh9 Sunday, March 20, 2016, 9:53 AM <br />