<br /> �R+�va�a�e�esnde�ntdlal&L! ' HVAC Loads Eltta Software I�evelopment,Inc.
<br /> 'R ght Commerclal
<br /> g Cooling � Waaddala`Piarce Res
<br /> cAndover MN 55304 p e,�
<br /> 7"otal8uildin Summa Loads
<br /> Corpp'on�'nt Aree �an L�'E �eh rotai,.
<br /> �Dascn tion� � Quan Losg 0�i� �.�in �ain;
<br /> Andersen: Glazing�operable window,woad sash, u-value 380 9,389 0 9,907 8,907
<br /> 0.29, SHGC 0.32
<br /> 4A-6-d: Glazfng-Double pane low-e(e=0.20 or less), 118.4 3,321 0 1,123 1,123
<br /> high perfarm2nce, sliding glass door,e=0.05 on
<br /> su�face 2, any frame, outdoor insect screen with 50%
<br /> coverage, u-valua 0.33, SNGC 0.33
<br /> 19N: Door-Metal -Polystyrene Core 44 1,309 Q 370 370
<br /> 12F-psw: WaII�Frame, R�21 insulatian in 2 x fi 5#ud 21p8.8 11,648 0 1,823 1,823
<br /> cavity, no baard insulation, siding finish,woad studs
<br /> 1560-10sf-4:Wall-Basement, , R-10 board insulation to 343 �,574 0 D 0
<br /> flaor, no interior finish,4'flaor depth
<br /> 1580-10sf-8:Wall-�asemenk, , R-10 board inaulation to 399 9,96�4 0 75 7S
<br /> floor, na interior flnish, 8'floar depth
<br /> "i6B�50: Roof/Ceiling-UnderAtticwith InsulationonAttic �779 3,024 � 1,7Q8 '{,7p8
<br /> Flaor(also use for Kn��Walls and Pa�titian
<br /> Cellings),Vented Rttic, No Radiant Barrler, Dark
<br /> Asphalt Shingles or Dark Metal,Tar and�ravel or
<br /> M�mbrane, R-50 insulation
<br /> 21A-32: Floar-Basament, Concrete slab, any thickness, 2 174B 2,9B8 0 0 0
<br /> or more feet below grade, no insufatlon below floar,
<br /> any floor cover, shortest side oF floor slab is 32'wide
<br /> 20P-30: Floor-Over op�n crawl space or garage, Passive, 33 98 Q 9 9
<br /> _R_30.blanket insulation, an�cover __
<br /> __ ..._.-._ _.-.------ ._... . _ ___._ ._ ......._ ......------------_ _ ..
<br /> Subtotals for structure: 35,276 0 15,015 15,015
<br /> Peopla: 4 800 920 1,720
<br /> Equipment: 801 6,020 6,821
<br /> Lighting: 0 0 0
<br /> Ductwork: 0 0 0 0
<br /> Inflltratlon: Winter CFM:46, Summer CFM: 23 4,212 360 322 682
<br /> Ventilation:Winter CFM: 131, Summer CFM: 131 4,754 2,032 727 2,759
<br /> Humidificatian (Winter)8.15 gsl/day: 2,988 0 0 0
<br /> AEDExcursion:._.. __.._.__.____. .._.._..... . ... . ._.. .__...____.---�.__.-------�--- 4,140_.-�---�-�140
<br /> __ .
<br /> Total Buflding Laad Totals: 47,229 4,093 27,944 39,237
<br /> Ghe� Fi,..u��s
<br /> Tatal Building Supply CFM: 1,28$ G�'M Per Square ft.: 0_351
<br /> Square ft.of Room Area: 3,525
<br /> Volume(ft')of Cond. Space: 34,344
<br /> guildin' I���ds
<br /> Total Heating Required Including Ventilation Air: 47,229 �tuh 47.228 MBH
<br /> Total Sensible Gain: 27,144 Btuh 87 %
<br /> Total Latent Galn: 4,093 Btuh 13 �,6
<br /> Total Cooling Required Including Ventilation Air: 31,237 Btuh
<br /> Notes �
<br /> Rhvac is an ACGA epproved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J Sth Edltion, Verslon 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> �a sura to select a unit that meets both sensible and latent loads according to the manufacturer's performance deta at
<br /> your design conditlons.
<br /> C:1UserstKurtlDocumenislElite SoftwarelFZhvac 9 Proj�ctslWooddala Pierce res.,rh9 Friday, January 29,201�, 11:33 AM