My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00157 - New house
Orono
>
Property Files
>
Street Address
>
B
>
Boulder Drive
>
787 Boulder Drive - PID: 33-118-23-11-0132 - New PID
>
Permits/Inspections
>
2016-00157 - New house
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:05 PM
Creation date
5/12/2016 11:01:22 AM
Metadata
Fields
Template:
x Address Old
House Number
787
Street Name
Boulder
Street Type
Drive
Address
787 Boulder Drive
Document Type
Permits/Inspections
PIN
3311823110132
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r . � . <br /> GENERAL NOTES: <br /> 1. Wall thicknesses noted are nominal unless specifically stated otherwise. <br /> 2. Maximum wall to footing centerline offset is 2". A minimum of 2"of footing is to extend on each side of the wall. <br /> 3. Bar laps when required are to be at least 40 bar diameters for grade 40 and 60 bar diameters for grade 60. <br /> 4. Bend horizontal bars or provide matching hooks around all wall corners and intersections. <br /> 5. Horizontal bars may be placed anywhere within the wall thickness provided 2"minimum cover is provided. <br /> 6. Allowable bar placement tolerance is 1/2". Tying is not required if tolerances are met and maintained. <br /> 7. Dowels may be drilled and installed afterfooting pour unless otherwise noted. Vertical bars may be embedded <br /> into footing in place of dowels at the same embedment. Vertical bars and dowels do not need to align. Dowels <br /> may be bent down for safety and covering then bent back before wall placement. <br /> 8. Sill plate sections require at least two anchors with one within 4"to 12"of each end and at all corners and <br /> intersections. Walls less than 24"in length require only one anchor. Sill plates may overhang the face of the wall <br /> provided the overhang is not loaded vertically and all anchor bolUconnection tolerances are met. <br /> 9. Anchor bolts 1/2"or larger in diameter do not require corrosion protection per IRC section R317.3.1 exception 1. <br /> 10. Anchor bolts may be substituted with 1/2"diameter threaded rod epoxy grouted at same spacing with 7"embed. <br /> 11. The presence of form oil on the reinforcing is acceptable for the conditions contained in these drawings. <br /> 12. Slope grade 6"minimum downward away from foundations within first 10 feet or provide Code adequate swale. <br /> 13. Do not backfill until the concrete has reached at least 70 percent of the 28 day concrete strength. Use of <br /> adequate shoring is required when the final floor and slab systems are not in place and fully anchored. <br /> COLD WEATHER GUIDELINES: <br /> The following information is general guidelines for the placement of concrete in cold weather conditions. It is the <br /> contractor's responsibility to ensure proper means and methods are followed and that the final in place product is <br /> adequate. <br /> 1. The contractor is to work with the concrete supplier to obtain a mix design which accounts for the conditions <br /> expected. Use of extra cement,early-strength concrete, and accelerators are recommended attemperatures <br /> below 20 degrees F. <br /> 2. Concrete is to be delivered to the site in a timely manner. <br /> 3. Placement of concrete earlier in the day to take advantage of latent heat of sunlight is advised. <br /> 4. Do not add additional water. Using water-reducing admixtures is recommended when required. <br /> 5. Forms are to be free of snow and ice. Do not place concrete in contact with frozen ground, snow, or ice. <br /> 6. Preheating of rebar is not required, however it is to be free of frost,snow,and ice. <br /> 7. Use of form blankets or other approved protection is highly recommended for the top of the wall at temperatures <br /> below 10 degrees F and for the whole wall when below zero degrees F. <br /> Oswell Engineering and Consulting, L.L.C. 1901 E Hennepin Ave,#201 .. ° ' `:�;�� <br /> Project Name: 2016 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 ' <br /> Description: General Notes Phone:612-720-4639 '`��' '� <br /> � <br /> Project# 15.100 Fax:612-886-2966 <br /> Client Name: Manor Concrete Construction, Inc. www.oswellec.com <br /> Client Address: 11225 90th Ave N, Ma le Grove, MN 55369 Page S2 of S6 "�,t '; <br /> 1/1/2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.