My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00157 - New house
Orono
>
Property Files
>
Street Address
>
B
>
Boulder Drive
>
787 Boulder Drive - PID: 33-118-23-11-0132 - New PID
>
Permits/Inspections
>
2016-00157 - New house
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:05 PM
Creation date
5/12/2016 11:01:22 AM
Metadata
Fields
Template:
x Address Old
House Number
787
Street Name
Boulder
Street Type
Drive
Address
787 Boulder Drive
Document Type
Permits/Inspections
PIN
3311823110132
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y � <br /> Christine Mattson <br /> From: Adam Edwards <br /> Sent: Thursday, March 10, 2016 3:44 PM <br /> To: Christine Mattson <br /> Subject: RE: 787 Boulder Drive/#2016-00157 <br /> Chris, <br /> Approved the plan with comments: <br /> The retaining wall depicted are depicted right the threshold for requiring a design signed by a professional <br /> engineer. Tiered walls are considered one wall unless they are separated by at least twice the height of the higher wall <br /> are considered one wall. Should the walls be constructed closer together than depicted or should the top wall increase <br /> in height, a design will be required. <br /> Adam <br /> From: Christine Mattson <br /> Sent:Thursday, March 10, 2016 3:01 PM <br /> To:Adam Edwards<aedwards@ci.orono.mn.us> <br /> Subject: FW: 787 Boulder Drive/#2016-00157 <br /> We have received an updated survey for 787 Boulder Drive. Please review and provide comments. <br /> Thanks! <br /> From:Adam Edwards <br /> Sent:Thursday, March 03, 2016 4:00 PM <br /> To:Christine Mattson<CMattson@ci.orono.mn.us> <br /> Subject: RE: 787 Boulder Drive/#2016-00157 <br /> Chris, <br /> I've reviewed the subject plan and offer the following comments: <br /> 1. The site plan and construction plans do not agree. The east side Elevation of the building plans depicts a stone <br /> retaining wall which is not depicted on the site plan. The inclusion of a retaining wall will impact the overall <br /> grading and drainage plan of the site.The retaining wall is depicted at^'4ft. Walls 4' or greater in height must be <br /> designed by a licensed professional, and plans must be submitted to the City for review prior to the approval of <br /> the permit. <br /> 2. The plan notes call for the installation of rock construction access but do not depict its location. The locations <br /> for such an entrance are limited. Special care must be exercised to ensure the existing driveway servicing the <br /> neighboring homes is not damaged or blocked and that the hydrant and water curb stops are not damaged <br /> accessing the site. <br /> 3. A separate permit for utilities connections will be required. <br /> 4. Perimeter erosion control measures should be installed by the Contractor and inspected by the City prior to any <br /> work, including demolition. Contractor must provide minimum 24 hour notice prior to inspection. <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.