Laserfiche WebLink
. � <br /> � Compliance Inspection Form for Existing <br /> Individual Sewage Treatment Systems <br /> � <br /> This form reflects the requirements of the 1996 version of MN Rules Chapter 7080 <br /> Minnesota Pollution Control Agency <br /> Note:Local inspection standards may be more or less restrictive than the state requirements. These differences must be made available by the Local <br /> Unit of Government. <br /> Date of Inspection: �'�' <br /> Property Owner(s) Telephone( )� <br /> Person requesting inspection(if different than owner) Telephone ( ) <br /> Reason for inspection: , , .-� <br /> Site Address City , <br /> Zip Code Unit of Government Regulating this property <br /> Fire No. Parcel No. Township Name <br /> Township Rangc Section Quarter <br /> (Check appropriate sewer system component and indicate location on site sketch). <br /> Tank s : Soii Treatment System: Other(briefly describe�: Flow Meter <br /> �-Septic tank Rock trench _Alternative system <br /> _Aerobic tank _Gravelless pipe trench _�xperimental system Yes No <br /> ,�Pump tank _Chamber trench _Warrantied system If yes, <br /> Holding tank Seepage bed Exp. Date: <br /> Other �`,�. Mound Other <br /> _At-grade <br /> Svstem Classification <br /> System Built Prior to April 1, 1996 and not Located in Any System located in Shoreland or Wellhead <br /> Shoreland or Wellhead Protection Area or Serving a Protection Area or Serving a Food, Beverage or <br /> Food, Beverage or Lodging Establishment Lodging Establishment, plus all systems Built after <br /> April l, 1996 <br /> Is the sxstem an imminent Qublic health threat(IPHT,L Up_grade Is the system an IPHT? Upgrade <br /> 1.Discharge of sewage to the ground surface? YES NO 10 mo 1.Discharge of sewage to the ground surface? YES NO 10 mo <br /> 2.Dischazge of sewage to draintile 2.Discharge of sewage to draintile or <br /> or surface waters? YES NO 10 mo surface waters? YES; ,I�IO.,10 mo <br /> 3.Sewage backup into dwelling? YES NO 10 mo 3.Sewage backup into dwelling? YES�TrO:'10 mo <br /> 4.Situation with the potential to immediately and 4.Situation with the potential immediately and ^`� <br /> adversely impact or threaten public health or adversely impact or threaten public health or s--�� <br /> safety? YES NO ]0 mo safety? YES(`NO ?0 mo <br /> Is the svstem failing? Is the system failing? `" <br /> 5.Less than TWO feet of vertical separation between 5.Less than THREE feet of vertical separation between , <br /> system bottom and saturated soil or bedrock? YES NO LGU** system bottom and saturated soil or bedrock? YES� NQ,,LGU** <br /> 6.A seepage pit,cesspool,drywell,or leaching pit? YES NO LGU** 6.A seepage pit, cesspool,drywell,or leaching pit?YES; NO LGU** <br /> ** LGU=Local Unit of Government ordinance must specify the time period within which the system must be upgraded. <br /> STATUS OF THE SYSTEM <br /> Based on the compliance criteria above the system status is (check one)�'in compliance(functioning)�failing�an imminent threat <br /> therefore,this document is a(check one)�3"Certificate of Compliance ❑No[ice of Noncompliance. <br /> Page 1 of 2 <br />