Laserfiche WebLink
J <br /> � ' <br /> 08-12-1994 TJBeam(TM) Page 1 of 2 <br /> TJBEAMD v4.20 sn�214011640 1111 <br /> DFP PLANNING � DESIGN <br /> a%9i NWY, 10 NE ARDEN HILLS, MN �5112 USA Phone� b36-68�9 <br /> ------------------------------------------------------------------------------------------------------------------------ <br /> Name� DFP PLANNING & DESIGN Project Name� Page iitle� <br /> Based on ALLOWABLE STRESS DESIGN ( ASD ) UBC building code for TJM products available through Distribution <br /> ------------------------------------------------------------------------------------------------------------------------ <br /> Application........ Roof - Heavy Deflection Criteria (MR) Member Use................. Beam <br /> Load Classification..,..... Snow LL Defl TL Defl Member Top Slope(in/ft)... 0.000 <br /> load Duration factor.....,. 1.00 Span 1 L/360 L/240 Roof Slope(in/ft)..,.,,,.. 0.000 <br /> Live Load(psf}............. 40.0 Span 2 L/360 L/240 Floor Decking.,...,.,,.,,,,. N/R <br /> Dead Load(psf)............. 15.0 Repetitive Member Use....... N/A <br /> Partition Load(psf)........, 0.0 Reinforced Overhangs..,,.... N/A <br /> Tributary Width( '-').... 1- 0.00 <br /> LORD� Class LDf Begin End Live Load Dead load Comment <br /> 1 Unif(plf} Snow 1.00 0'- 0.00' 2'- 9.00' 440 165 Add <br /> 2 Unif(plf) Snow 1.00 2'- 9.00' 18'- 9.00' 180 293 Add <br /> 3 Unif(plf} Snow 1,00 18'- 9.00' 25'- 6.00' 440 165 Rdd <br /> 4 Unif(plf) Snow 1.00 0'- 0.00' 25'- 6.00' 120 45 Add <br /> 5 Conc(lb} Snow 1.00 2'- 9.00' 0 5000 Add <br /> Copyright (c) 1993 by Trus Joist MacMillan, a limited partnership, 8oise, Idaho, <br /> MICRO=LAM(R) is a registered trademark of Trus Joist MacMillan. <br /> TJBeam(TM) is a trademark of Trus Joist MacMillan. <br />