Laserfiche WebLink
� o� <br /> , o�� o <br /> � ���� �� � CITY of ORONO <br /> ��,� '����r� -�� �, <br /> r�' �� <br /> �y, � ,�� '�P�� �� ti Municipai Offices <br /> '� `��;�`;���I����� G�' <br /> �� „ ��., ,e� ,�.g.� Street Address: Mailing Address: <br /> �f'EggO 2750 Kelley Parkway P.O. Box 66 <br /> Orano, MN 55356 Crystal Bay, MN 55323-0066 <br /> . � <br /> Owner: ` � �� Address: 2755 Countryside Dr. W. <br /> Permit #'s: 89 2 Dates: 5/1/97 Contractors: Clover Sill Co. <br /> (This is [ ] an existing system [ �] new construction) . <br /> STEM COMPLIANCE (1-3) : 1 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil leval [�j has or [ ] has not been identifiad at this time. If the <br /> saturated soil level has not been identifiad, this classification is subject to ravision. ) <br /> K CONDITION (5-9) : 5 <br /> 5 Pumpout not needed at this time. <br /> Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintanance Pumpout the tanks � were or [ J ware not confirmed <br /> to be watertight by the licansed pumping contractor. If the tanks were not confirmad to be <br /> watertight, this classification is subject to ravision.) <br /> D INFIELD CONDITION (11-14) : 11 <br /> 11 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low <br /> COMMENTS: <br /> � ' L"�J <br /> Dat�f Inspection Septi System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />