CFT F('TTRT� THE CORRECT SIZE H-SERIE� EATER
<br /> For Your Swimming Pool For Your Spa or Hot Tub
<br /> Determine your pooPs surface area in square feet Derermine your spa capacity in gallons(Surface area x average
<br /> depth x 7'/J �
<br /> _�,
<br /> q L B R � The reference table lists the time required in minutes to raise the
<br /> temperature of the spa/hot tub by 30°F Locate in the table below
<br /> yy the spa/hot tub size in gallons equal to or just greater than the spa/hot
<br /> tub size in gallons. Select the desired time to raise the spa/hot tub
<br /> Area=(A+B)x L x.45 Area=R x R x 3.14 Area=L x W temperature 30°,read to the left and select[he appropriate H-Series
<br /> model.
<br /> Locate in the table below,the surface area equal to or just This guide can be adjusted for other temperature rises.For example,
<br /> greater than the pools surface area, read to the left and select if you desire a 15°F increase in temperature,simply di��ide the time for
<br /> the appropriate H-Series model. 30°F rise by the ratio of 30/15=2.
<br /> For indoor pool installations divide the pool's surface area by 3. Note: Heat losses and/or heat absorbed by spa walls or other objects
<br /> will add to the heat-up time.
<br /> Spa sizing is based on an insulated and covered spa.Always cover your
<br /> Recommended H-Series Model spa or hot tub when not in use to minimize heat loss and evaporation.
<br /> Model Surface Area Recommended H-Series Model
<br /> H-400 1200 Spa/Tub Size in Gallons
<br /> _ _ _ _.. _ _ ._
<br /> H-350 1050 _.. . .
<br /> --.... .. . - .. ... Model 200 300 400 500 600 700 800 900 1,000
<br /> H-300 900 _. __ _ _ _. . ..
<br /> - - - --- --- - Tme m Minutes to Raise SpalTub Temperature 30°F
<br /> H-250 750
<br /> -- - - H-400 9 14 19 23 28 33 37 42 47
<br /> H-200_ 600 _ . . . . . ._..... ..... . .. . ..._ _ ._ __ _ . ...
<br /> _ _ __ ___ ._ _. .. . . __. . .. .. H-350 11 16 21 27 32 37 43 48 54
<br /> H-150 450
<br /> _ .. _ .......... . ........... . ....... _. ..._......... .... ..... _.
<br /> H-300 12 19 25 31 37 44 50 56 62
<br /> Table is based on a 30°F temperature rise,3'/,MPH - - - - - "
<br /> average wind velocity and elevation of up to 2,000 feet H 250 15 22 30 37 45 52 60 67 75
<br /> above sea leveL H-200 19 28 37 47 56 66 75 84 94
<br /> _. ,.. _...._.. ....__ _........ ......_._._..............._.. .. ...._._..._..._............_..._._.
<br /> H-150 25 37 50 62 75 87 100 112 125
<br /> Specifications and Dimensions �
<br /> Gas �
<br /> BTU Flue Outlet Flue Pipe Stack Height Heater Connection
<br /> Model /Hr. Width Depth Height Diameter Diameter DHI HWS Weight(Ibs.) at Heater
<br /> _ _ _ _ . _. _ ..... . . . __ .. . _..._ _._ ... ....... .... ..._... ... , ........... ._ ...__...,... ___ ......... . _. _
<br /> H-400 400,000 35'/<" 27 f" 28 f" 9" 10" 31 f" 19 f" 200 Ibs. 3/4'
<br /> __ _.. _ _ _ _ __ . . ..._. .. ....._... ... _ _. _. . ..... .. ___....... .... . ...._..._.. ,........ . __.. . _....... . . _ _._ .. ...._...... .
<br /> H-350 350,000 32 f" 27 f" 28 f" 9" 10" 31 ;4" 17 '/.' 185 Ibs. 3/4'
<br /> _ __. _ _........ ._ ........ .... .. .... __. ... ............ _. __ .. ..__ . ... ... _.__......_._.
<br /> H-300 300,000 2g'/." 27;�" 28,�4" 8" 9" 30'/<" 17 Y." 157 Ibs. 3/4'
<br /> _ _ _ _ ____ ... .. .. _ ....... .... .........._._ . .. .. . .. .._ ... ._.. _....... ...._._.... __._... _............. ........_..
<br /> H-250 250,000 27" 27 f" 28,/" 7" 7" 28 Y<" 17'/<" 144 Ibs. 3/4"
<br /> __ __ _ ..... ....... .. ._ ...... ....._... .. _... _._........... . ... _...... ,. ..... .. ..._.. _.... . . ........ ..__........ ............. _...._._.. __... _.
<br /> H-200 200,000 24'/<" 27 f" 28'f" 7" 7" 28 Y<" 15 Y." 141 Ibs. 3/4'
<br /> _. . . _. .. . __. _._.. .... . .. .. . __...... .. ..._..._ ............ _ ......... _ _ __... .. .. _ . ...._... .
<br /> H-150 150,000 21 '/<" 27 f" 28;4" 6" 6" 22 Y<' 14" 131 Ibs. 3/4'
<br /> H-Series heaters are available in a comprehensive range of BTU sizes and options, and natural or propane gas. All units are certified by the American Gas Association
<br /> including 1!"and 2"water connections,millivolt and electronic temperature control, and carry Hayward's exclusive warranty.
<br /> _�.—_.-•.�,.�
<br /> y�'s.� '"'� `w'"" �"'��"`�'"i°"`�"` • H-Series heaters feature
<br /> '� --- , • � ,_ ,.._ ._..µ
<br /> •"° � . �1. ""Y , ,n water connections that are
<br /> � �y..: t '� '�� :- ' �� � f :. �•= ,' � fully compatible with
<br /> �
<br /> ��..,�. � - , �.. ., � ��,o
<br /> � � �'� C �� ;�� � �;� �-� �, preexisting installations.
<br /> ;I �
<br /> V� �� � f � �� L
<br /> �� ,'�'
<br /> ���a ' �� 1. 4 ; � i,, o`R"
<br /> ''�4 *;?. , ' .: . , ,. , ;1�; � ��^` �,
<br /> �� ' �
<br /> The Hayward H-Series family of high-performance heaters. � °"��F,�
<br /> HAYWARD POOL PRODUCTS, INC. �
<br /> Hayward Pool Products, Inc. Hayward Pool Products, Inc. Hayward Pool Products Canada Hayward S.A.
<br /> 900 Fairmount Avenue 2875 Pomona Boulevard 2880 Plymouth Drive Zone Industrielle de Jumet
<br /> p Elizabeth,NJ 07207 Pomona,CA 91768 Oakville,Ontario L6H 5R4 B-6040 Charleroi�Belgium)
<br />
|