ACFoam� Roof Insulation <br /> � , , � � � . � � � . <br /> Nominal Thickness Pieces per Package 4 X 8Square Feet per Package4' x 4' � <br /> 1.0" 46 1472 736 <br /> 1.5" 31 9922 496 <br /> 1.8" 26 832 416 <br /> 2.0" 23 736 368 <br /> 2.5" 18 576 288 <br /> 2J" 17 544 272 <br /> 3.0" 15 480 240 <br /> 3.4" 14 448 224 <br /> Packages per 45' Truck 22 44 <br /> � <br /> All ACFoam Roof Insulation Products may be installed with or with- no other represent�itions or warranties as to the insulalion sold <br /> out a vapor retarder, the need for which is determined by the design- herein. The Seller disclaims all other warranties, express or <br /> er. Before installation, the deck should be firm, well attached, even, implied, including the warranty of inerchantability and the war- <br /> dean and dry. Proper attachment of the insulation is necessary to ranty of fitness for a particular purpose. Seller does, however, <br /> prevent roof failures. Atlas will not be responsible for any damage have a limited warranry as ro the R-Value of the insulation, the <br /> caused by improper attachment ACFoam products can be attached terms of which are available upon request from Seller. <br /> to decks that are approved by FM and local codes.The responsibility Limitation of Liability:The Seller shall not be liable for any inciden- <br /> to determine the suitability of the deck is that of the designer/specifi- tal or conseyuential damages including the cost of installation, <br /> er and/or owner's representative. Roof insulation which has become removal, repair or replacement of this product. The Buyer's reme- <br /> wet and/or damaged should be removed and replaced with solid, dies shall be limited exdusively to, at Seller's option, the repayment <br /> dry insulation. Surface protection such as plywood must be used in of the purchase price or resupply of a like quantity of non-conform- <br /> areas where heavy and/or repeated traffic is anticipated both during ing product. Atlas distributors, agents, salespersons, or other inde- <br /> and after installation. pendent representatives have no authoriry ro waive or alter the <br /> Where possible, a two-layer application of ACFoam is strongly rec- above limitation of liability and remedies. <br /> ommended. The joints in each layer should be offset in order to Warning- Do Not Leave Exposed:This product is a polyiso organic <br /> avoid a vertically continuous joint through the total insulation thick- plastic foam and will bum if exposed to an ignition source of suffi- <br /> ness. Two layers (or more) with joints staggered can provide cient heat and intensity,or open flame,such as a welder's torch. Like <br /> improved insulation performance by eliminating thermal bridges. other organic materials,this product will release smoke if ignited. Do <br /> This method also reduces condensation potential and thermal stress not apply flame directly to ACFoam Roof Insulations. This produd <br /> on the roof inembrane. should be used only in strict accordance with Atlas recommended <br /> Mechanical Attachment: Mechanical fastening is the preferred uses and application instructions. <br /> method of attachment Fastener frequency and spacing are covered <br /> in the Atlas Roof Insulation Catalog according to the membrane sys- <br /> tem. Refer to FM Loss Prevention Data Sheet 1-28 for special consid- � � � � � <br /> erations regarding perimeter and comers of the roof. <br /> Bitumen Attachment:When mechanical fastening is not preferred or For additiondl infonnation, contact your loCal <br /> may not be practical, such as on concrete decks, hot applied bitu- Atlas Dlstrlbutor. <br /> men may be used (except for ACFoam Supreme). When using � � <br /> asphalt on concrete decks, priming is necessary. Precautions must be ,�`� <br /> taken to prevent bitumen drippage.When using hot applied bitumen � <br /> for attachment, care must be taken to apply the bitumen in sufficient STRtJCTURAL�MOO� <br /> quantity to totally cover the available deck surface (18-30 Ibs. per CORPORATION <br /> square).To assure embedment,the board must also be stepped on at ' <br /> several points while the bitumen is still hot enough to allow for posi- 4000 LABORE RD. ■ ST. PAUL, MN 55110 <br /> tive attachment. The recommended ACFoam insulation size for hot PHONE (612) 426-8111 <br /> asphalt attachment is 4' x 4'. Due to the uneveness of solid decks, FAX (612) 426-6859 ■ WATS (800) 652-9058 <br /> 4'x 8'boards are not recommended for bitumen attachment to the <br /> deck,but may be mechanically fastened. <br /> For proper attachment of insulation to lightweight insulating con- <br /> crete decks or poured gypsum concrete decks, follow the instruc- <br /> tions outlined in the NRCA Roofing and Waterproofing Manual. ATLAS ROOFING CORPORATION <br /> ACFoam products must not be adhered directly to these decks by <br /> any bitumen or adhesive attachment method. 1775 The Exchange, Suite 160 <br /> Warranty: Other than the aforementioned representations and Atlanta,Georgia 30339 <br /> descriptions, Atlas Roofing Corporation (hereafter, "Seller") makes <br />