My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-01069 - pool
Orono
>
Property Files
>
Street Address
>
C
>
Countryside Drive West
>
2650 Countryside Drive West - 04-117-23-12-0014
>
Permits/Inspections
>
2013-01069 - pool
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:07:09 PM
Creation date
5/2/2016 3:54:03 PM
Metadata
Fields
Template:
x Address Old
House Number
2650
Street Name
Countryside
Street Type
Drive
Street Direction
West
Address
2650 Countryside Dr W
Document Type
Permits/Inspections
PIN
0411723120014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> CIVIL�ESIGN <br /> PROFESSIONALS <br /> ORONO COPY <br /> Oct 18, 2013 <br /> Tim Johnson <br /> Southview Design& Construction <br /> RE: Jorgenson Residence Retaining Wall(13-692) <br /> Long Lake, Minnesota <br /> Design Assumptions: <br /> Fieldstone Boulders, 15°Wall Batter <br /> Coulomb Design <br /> Live Load: None <br /> Dead Load: None <br /> Toe Slope: None <br /> Back Slope: 25H:1V MAX <br /> Seismic: N/A <br /> Bearing Capacity: 3,000 PSF <br /> Soil Design Properties: <br /> � y c <br /> Retained Soil 30° 120 PCF 0 (Pit Run Sand) <br /> Foundation Soil 26° 120 PCF 0 (Sandy Lean C(ay) <br /> Notes: <br /> No soils information was provided for this preliminary design. The onsite material is assumed to be a sandy <br /> lean clay with an internal friction angle of 26°. Where unsuitable soils are found, a subcut may be required <br /> and structural fill shall be placed and compacted to provide an adequate bearing foundation. The design <br /> requires a pit run sand with an internal friction angle of 30° to be used in the retained zone. The above <br /> minimum soil strength parameters shall be verified prior to final design. CDP shall be contacted if the aUove <br /> soil strength parameters cannot be met and a redesign may be required. <br /> Wall layouts and elevations obtained from Southview Design Landscape Plan dated 10/11/2013. <br /> A gloUal stabiliry analysis has not been performed because of the lack of geotechnical information provided. <br /> The project geotechnical engineer shall complete a global stability analysis based on the final wall design and <br /> the actual design parameters from the onsire soils. The results of a global stability analysis may cause design to <br /> change. <br /> We appreciate the opportuniry of providing services to you. If you have any questions or comments regarding <br /> this project, please feel free to contact us. <br /> Sincerely, <br /> Civil Design Professionals <br /> Steven R. Schilling <br /> Civil Desi�n Professional� . 8609 Ly�ndale Aae.S.,Suite 200 Blooinington,MN 55420 . Ofh�e(95'_)30i-5312 . w��.�dp-��.���o� <br />
The URL can be used to link to this page
Your browser does not support the video tag.