My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-01197 - septic mound repair
Orono
>
Property Files
>
Street Address
>
C
>
Countryside Drive
>
2590 Countryside Drive - 04-117-23-11-0010
>
Septic
>
2012-01197 - septic mound repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:05:58 PM
Creation date
4/29/2016 3:58:44 PM
Metadata
Fields
Template:
x Address Old
House Number
2590
Street Name
Countryside
Street Type
Drive
Address
2590 Countryside Dr
Document Type
Septic
PIN
0411723110010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' , • . �7"P TESTING� INC. Steven B. Schirmers • MPCA Cert.No. 627 <br /> 951 Katydid Lane NE • St. Michael, MN 55376 • (763) 497-3566 <br /> FAX (763)-497-5011 <br /> State License#394 <br /> October 11, 2012 <br /> Melissa Murphy melissamurphy@edinareaity.com <br /> 2590 Countryside Dr. <br /> Orono, Henn. Co., MN <br /> A site evaluation was completed for a new system for this property due to the existing <br /> system being non-compliant. The only areas available for a new system were either fill, <br /> excavated or compacted soils & are not suitable for a new system. <br /> The proposal is to remove the existing mound from the upslope edge of the rock bed to <br /> the downslope toe. This must be completed with minimum trave over the site. The <br /> rockbed is ponding & will need to be exposed & the eflluent pumped out. The trees on <br /> the mound will need to be removed. The new sand will be placed with the bottom of the <br /> rock bed at elev.113.0. <br /> The existing tanks may be used upon a T�nk Integrity report passing. <br /> The supply line will need approximate(y 60' replaced to manifold at the east end of the <br /> rockbed. <br /> The manifotd and supply line pipe must have back drainage to the pumping chamber. <br /> The distribution pipes shall h�ve their ends capped. Be sure the rock and sand fill <br /> material are clean. The sod layer below the entire mou�ded area must be turned over, <br /> just break up the sod, be sure not to over work. <br /> If the tanks have less than 2' of cover, the lids, risers & maintenance hole covers must <br /> be insulated to a value of R10. <br /> An effluent screen will be needed at the outlet of the 2nd tank, which needs ta be <br /> cleaned 2 times a year if a garbage disposal is installed. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.