Laserfiche WebLink
i-��\ <br /> %j / O <br /> %/�' � �\ <br /> O O <br /> �� � CITY of ORONO <br /> � r ���. _ � � <br /> , <br /> �,, ��j, a� '�� � ,� MunicipalOffices <br /> �� � `� ; �� ,;`� G �;' <br /> Street Address: �15�.-a4q-�I6o o Mailing Address: <br /> � t� � ;�;� � �,� ����' <br /> xESHO 2150 Kelley Parkway P.O. Box 66 <br /> - "� Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: a� �� �o�^���5�,��C �C'_ <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITI' 1-3 : I <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards ofthe current Orono Municipal Code. <br /> Z "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or eazlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stanchrds of the current Orono Municipal Code and which is faIling for any <br /> reason;and any ISTS with less than thre�feet of unsaturated soil or sand betw-een the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-71: � <br /> Tanl:inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> �Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tanl:was last pumped 5 -Z.-��'C 1 � <br /> Make sure septic tanks are pumped through manhole and not through white inspection pipes This allows for the proper <br /> cleanin�. Keep water softner and iron filter discharge out of septic sVstem to prolong life of drainfield Ask pumper to test <br /> alarm float to verifv alarm is still working in Vour house. The alarm warns owner that septaEe is about to backup into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION 8-10 : �5 <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> COMMENTS: !"`ou�� � ae�S �� _ �vMp SC�t-�� ��S��S <br /> Sa��� �oc�- 3 yc1 <br /> ����-o y �1r``r�� .� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />