Laserfiche WebLink
, <br /> � <br /> FASTENMASTER TECHNICAL BULLETIN <br /> � ' 1 1 � 1 � <br /> The FastenMaster Timberlok load values in Table 1 can TABLE 1 <br /> be used by a design professional to determine suitability <br /> of these fasteners in a rafter to top plate connection. ' <br /> • Where the uplift and/or lateral design loads have <br /> been provided on the building plons,the allowable yyood Species SPf/HF Douglas Fir Southern Pine <br /> loads in Table 1 can be compared to the plan values <br /> to make sure they are met or exceeded by use of this Lateral/ Lateral/ Lateral/ <br /> fastening method. Load Type Uplift Shear Uplift Shear UpIiR Shear <br /> • If ties or strops have been colled for to resist uplift Aliowable Load 420 320 540 380 620 410 <br /> and lateral forces, the allowable loads in Toble 1 <br /> should be compared to the manufacturer's published • Timberlok values above are bosed on ICC-ES Report#1078 and independentiy verified <br /> values for the specified connector to ensure that this �hrough testing to ASTM D-1761. <br /> fasiening method meets or exceeds these loods. • A standard wind load duration factor has been applied to these values per NDS Table 2.3.2. <br /> • In cases where the above iwo methods are not Other applicable NDS adjustment factors are at ihe discretion of a design professional. <br /> available and the wind speed from IRC Figure • These values apply only to the top plate to rafter connection and ossume that the fastener is <br /> 301.2(4) equals or exceeds 100 mph in hurricane- properly installed per the inshuctions on this bulletin. <br /> prone regions, or 110 mph elsewhere, the design <br /> loads of this connection can be determined by a <br /> design professional from one of the following three sources and compared to Table 1: <br /> l. American Forest and Paper Association (AfBPA) Wood Frame Construction Manual for One-and Two-Family Dwellings (WFCM). <br /> A sample of this chart is shown below. <br /> 2. International Code Council (ICq Standard for the Residential Construction in High Wind Regions (ICC-600). <br /> 3. Minimum Design loads for Buildings and Other Structures (ASCE-7). <br /> Sample Wind Loads <br /> Table 2 below represents common design wind loads on rafter to top plate connections taken from the AFBPA Wood Frame Construction Manual, <br /> High Wind Zone Exposure B,Wall Connections at Load Bearing Walls. <br /> TABLE 2 <br /> 12 16 20 24 28 32 36 <br /> WIND <br /> ZONE RAFTER LATERAL SHEAR <br /> (MPH) SPACING � (LB.) (LB.) <br /> 90 16"o.c. 82 96 110 125 139 154 168 119 52 <br /> 90 24"o.c. 123 144 165 187 209 230 252 178 78 <br /> 100 16"o.c. 124 147 170 193 217 240 264 145 64 <br /> 100 24"o.c. 186 220 255 290 325 360 396 218 96 <br /> 110 16"o.c. 170 203 236 269 303 336 370 176 77 <br /> 110 24"o.c. 255 304 354 404 454 504 554 264 116 <br /> 120 16"o.c. 220 264 308 352 397 441 486 209 93 <br /> 120 24"o.c. 331 396 462 528 595 bbl 728 314 140 <br /> 130 16"o.c. 275 331 386 442 499 555 bl l 247 109 <br /> 130 24"o.c. 413 496 580 664 748 833 917 370 164 g� <br /> <� <br /> This chart is used as an example only and should not be the sole source to design the connection. P W <br /> �� <br /> FastenMoster°'and Timberlok"are tmdemarks of OMG,Inc. <br /> Copyright OO 2009 OMG,Int.All rights reserved. <br />