Laserfiche WebLink
SEPTIC SYSTEM INVENTORY / <br /> Addr: 1920 Country Club Rd. PID: 27-118-23 42 0017 �"" <br /> Building Type : residence # BRs/GPD: 3 # Systems/units : 1/1 <br /> Permit No : 8179, Date of Permit : 11/12/85 Installer: Volkenant, Widmer <br /> System Type : mound Appliances : lndry <br /> SYSTEM CONDITION <br /> Conformity: 1 Tank Condition: 10 DF condition: 11 <br /> Failure Pot : low <br /> SEPTIC TANKS <br /> Material : precast concrete Capacity: 1000, 800 , 800 <br /> Setback to Bldg: 20 <br /> DRAINFIELD <br /> Length of Lines : 110 No. Lines : 3 Trench Width: 10 <br /> Treatment Area : 60*30 Type of Filter : rock, clean sand <br /> Tile Size : 1 . 5 Under Tile : 8 Perc Rate mn/in: 55 <br /> Setback DF-Bldg: 20 DF Ht above WT : 3 <br /> Soil Type : clay loam Limitations : water table <br /> WELL DATA <br /> Setbacks - Well-Tanks : 50 Well-DF : 75 <br /> Report in File? : y Pump Type : subm. <br /> Depth: 162 Diameter: 4 Method: drilled <br /> INSPECTION RECORD PUMPOUT RECORD <br /> Date Compliance Date Gallons <br /> 9/13/78 compliance-no surfacing s 9/5/92 2000 <br /> 6/20/84 surfacing near road 4 <br /> 7/19/85 no surfacing now, new grass growth; 2 <br /> 11/21/85 replacement installation 1 <br /> 7/25/86 no surfacing 1 <br /> 6/21/88 no surfacing 1 <br /> 10/8/90 no surfacing-pump tanks 1 <br /> 7/27/92 no surfacing-pump tanks 1 <br /> 9/19/94 no surfacing 1 <br /> 10/19/95 no surfacing-pump tanks 1 <br />