� .RHVAC-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. �
<br /> I Plymouth Plumbing&Heating Hansen Hometech-Gehl Addition �
<br /> � Brook'lyn Center, MN 55428-1662 ___ Page 1 i
<br /> i
<br /> ,'Total Building Summary Loads I '',
<br /> Component: TM�� �� ; Area Sen Lat ' -Sen :Total �
<br /> _; �-ry
<br /> � Description ' � ' �aT'�� . , Quan Loss Gain Gain Gain �
<br /> 3D Window Double Pane Low Emit Wood Frame 280 8,289 0 5,040 5,040 I
<br /> 11 C Door Metal Polystyrene Core 21 809 0 184 184
<br /> 121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 1383 6,237 0 1,414 1,414
<br /> 15G Wall 5' or More Below Grade 8/12" BIk+R-11 425 1,499 0 0 0
<br /> 161 Ceiling R-44 Insulation 1632 3,078 0 1,464 1,464
<br /> 19F Floor Over Basement/Encl Crawl Carpet No Ins,ulation 702 6,274 0 0 0
<br /> 19J Floor_Over BasemenUEncl Crawl Carpet+ R-30 930 1,335 0 0 0
<br /> Subtotals for structure: 27,521 0 8,102 8,102
<br /> People: 8 1,840 2,400 4,240
<br /> Equipment: 0 0 0
<br /> Lighting: 0 0 0
<br /> Ductwork: 3,887 0 0 0
<br /> Infiltration: Winter CFM: 114, Summer CFM: 153 10,017 3,214 2,443 5,657 i
<br /> Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336
<br /> Sensible Gain Total: 14,386
<br /> Temperature Swing Multiplier: X 1.15
<br /> Total Building Load Totals: 49,301 6,949 16,544 23,493 ;
<br /> j , Check Figures , �
<br /> Total Building Supply CFM: 776 (2.0 AC/hr) CFM Per Square ft.: 0.256
<br /> Square ft. of Room Area: 3,037 Square ft. Per Ton: 1,206
<br /> i � Building Loads 'I
<br /> ! Total Heating Required With Outside Air: 49,301 Btuh 49.301 MBH
<br /> Total Sensible Gain: 16,544 Btuh 70 %
<br /> Total Latent Gain: 6,949 Btuh 30 %
<br /> I Total Cooling Required With Outside Air: 23,493 Btuh 1.96 Tons (Based On Sensible + Latent)
<br /> 2.52 Tons (Based On 77% Sensible Capacity) �
<br /> � Notes
<br /> ! Calculations are based on 7th edition of ACCA Manual J. 'I
<br /> � All computed results are estimates as building use and weather may vary. ',
<br /> � Be sure to select a unit that meets both sensible and latent loads. �
<br /> I�
<br /> C:\elite\Rhvacw\Projects\Hansen Hometech - Gehl Addition.rhv Friday, August 08, 2003, 9:19 AM