My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-P10491 - addn/remodel/repair
Orono
>
Property Files
>
Street Address
>
B
>
Bracketts Point Road
>
1280 Bracketts Point Road - PID: 11-117-23-32-0019
>
Permits/Inspectiions
>
2006-P10491 - addn/remodel/repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:29:51 PM
Creation date
4/25/2016 12:57:23 PM
Metadata
Fields
Template:
x Address Old
House Number
1280
Street Name
Bracketts Point
Street Type
Road
Address
1280 Bracketts Point Road
PIN
1111723320019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Name: ROOF Customer:Chaska Building W0:283708 TI:A1 Qty:4 <br /> TC FORCE AXL HND CSI TC: 2x 4 SPF 1650E-1.SC Bottom chord has been loaded with 10 psf Joint Locations ' <br /> 1-. 2 -2028 0.04 0.55 0.59 BC: 2x 4 SPF 1650E-1.5C live load applied non-concurrently. 1) 0- 0- 0 7) 24- 6- 3 13) 10- 5- 5 <br /> 2- 3 -5036 0.26 0.40 0.69 2x 4 SPF #1/#Z (N) 14-15,10-11 MUI.TIPLE LOADCASES -- This design is the 2) 2- 5-13 8) 27- 0- 0 14) 4- 4- 0 <br /> 3- 4 -4611 0.35 0.33 0.66 �� Zx 3 SPF STUD (N) composite result of multiple loadcases. 3) 6- 0- 0 9) 27- 0- 0 15) 2- 9- 0 <br /> 4- 5 -4728 0.36 0.34 0.70 zx 4 SPF #1/#z (N) 2-14,7-11,0-0,0-0 All COMPRESSION Chords aze assumed to be 4) 11- 0- 0 10) 24- 8- 0 16) 0- 0- 0 <br /> 5- 6 -4572 0.34 0.36 0.70 2x 4 SPF STUD (N) 3-14,6-11,0-0,0-0 continuously braced unless noted otherwise. 5) 16- 0- 0 11) 22- 8- 0 <br /> WG: 2x 4 SPF �1/#2 (N) Bracing Schedule: 6) 21- 0- 0 12) 16- 6-11 <br /> 6- 7 -5032 0.28 0.40 0.69 �� or {}: Plate(s) OFFSET from joint center. Chords Max O.C. From To ------------ TOTAL DESIGN LOADS ------------ <br /> 7- 6 -2027 0.04 0.54 0.58 �e Joint Detail Report must be included TC 24.0" 6- 0- 0 21- 0- 0 Uniform PLF From PLF To <br /> with any submittal, inspection, and/or BC 72.0" 2- 4- 0 4- 4- 0 TC Ve=t L+D -90 0- 0- 0 -90 6- 0- 0 <br /> BC FORCE A7� BND CSI fabrication documentation. BC 72.0" 22- 8- 0 24- 8- 0 TC Vert L+D -90 6- 0- 0 -90 21- 0- 0 <br /> 16-15 1687 0.27 0.56 0.83 WndLod per ASCE 7-98, bS7F'RS, V= 90a�h, Bracing shown is for visual purposes only. TC Vert L+D -90 21- 0- 0 -90 27- 0- 0 <br /> 15-14 2457 0.60 0.28 0.88 H= 23.0 ft, I= 1.00, Exp.Cat. C, Kzt= 1.0 ----MAX. REACTIONS PER HEARING LOCATION----- BC Vert L+D -20 0- 0- 0 -20 27- 0- 0 <br /> 14-13 3219 0.52 0.10 0.63 Bld Type= pazt � 27.0 ft F� 27.0 ft Truss X-Loc BSet Vert Ho=iz Vplift Y Type <br /> 13-12 4747 0.77 0.13 0.90 in END zone, TCDIr 6.0 psf, BWIr 6.0 psf 0- 3-10 1 1485 -56 -363 B Pin <br /> 12-11 3222 0.52 0.10 0.62 � = 1.15 26- 8- 6 1 1484 0 -363 B H Roll <br /> 11-10 2454 0.60 0.29 0.89 PROVIDE UPLIFT CONNECTION PER SCHEDULE <br /> --------GLOBAL MAX DEEZECTIONS--------- <br /> 10- 9 1686 0.27 0.56 0.83 � � <br /> in./Ratio in./Ratio Jnt(s). <br /> Web FORCE Web FORCE I.Span -0.54/571 -0.85/363 5-4 <br /> 15- 2 -1569 5-12 -482 Horiz. 0.27 0.42 NA <br /> 2-14 2920 12- 6 1465 <br /> 14- 3 1745 6-11 1738 <br /> 3-13 1503 11- 7 2419 <br /> 13- 4 -458 7-10 -1565 <br /> 13- 5 60 <br /> ��-� is-0-� 6-�-� <br /> 1 2 3 4 5 6 7 8 <br /> 6.00 �.00 ' <br /> 6x6 1.Sx4 q 6x6 <br /> � � <br /> �3x8 �3x8] <br /> 3-7-4 3-7-4 <br /> � 0-7-4 �5x4 5x4]�-�"4 <br /> � 3x12 3x6 6x6 ,� <br /> 1- <br /> � � <br /> [8x12 .00 -8A x12] <br /> ,,2-0-0 ,, „2-0-0 ,, <br /> �� �� <br /> 1485#�5" 1484#7.25" <br /> ���2-0-0 „ 18-4 0 �����„ <br /> 16 15 14 13 12 11 10 9 <br /> 27-0-0 <br /> COSMETIC PLATES (8)1.Sx4 <br /> EXCEPT AS SHOWN PLATES ARE MiTek MT20 Scale=0.2419 <br /> WARNING: Eng Job: WO: 283708 <br /> � READ ALL NOTES ON THIS SF�ET. A COPY OF THIS DRAWING TO BE GIVEN TO <br /> ERECTING CONTRACTOR. BRACING WARNING: DWGJ: T I: A1 <br /> Bracing shown on lhis�awing is not aation brecmg wind brecing,patal bracing or ssnilar bracing which is a pan of the Dsgnr•SWD Chk• 10/12/200 6 <br /> building desig�and which mustbe crosidaed by the building desig�a.Bncmg shown is for late�al support ofUuss ' ' <br /> ����� embns only to rc�ce bucklumg length.Prwisions must be made to anchor laterel bacmg at mds and syaified locatia�s �r DF• 1.15 <br /> dnermined by the buildmg designc.Addaimal bracmg of the waall swceae may be required.(Sa HIBA1 or�ren.ea TC Live 35.0 psf • <br /> specifctrussbacingrequiremmLs,contac�builAingdesigna.(T�ussPlalel�sttlute,TPI�s laated at583D'Onofdo Plt DF� 1.15 <br /> Drie'e,Madison.R'iscrosin537�9), TC Dead 10.0 psf ' <br /> BC Live 0.0 psf O.C. : 2- 0- 0 <br /> TPI-95/IRC-00 <br /> BC Dead 10.0 psf Code: <br /> TOTAL 55.0 sf v5.0.18-4576521 <br /> Design: Matrix Analysis Profile Path: F:\trusjobs\263000\283708\ROOF\Al.prx <br />
The URL can be used to link to this page
Your browser does not support the video tag.