Laserfiche WebLink
Permit Number <br /> REScheck Compliance Certificate Checked By/Date <br /> 2000 Minnesota Energy Code <br /> REScheckSoftware Version 3.5 Release ld <br /> Data filename: D:�Documents and Settings\Owner\Desktop\REScheck�rambler calc.rck <br /> PROJECT TITLE: STONEBAY CONDOMINIUMS <br /> COUNTY:Hennepin <br /> STATE: Minnesota <br /> ZONE: 2 <br /> CONSTRUCTION TYPE: Multifamily <br /> DATE:09/21/04 <br /> DATE OF PLANS: 8/4/03 <br /> PROJECT DESCRIPTION: <br /> RAMBLER TOWNHOMES <br /> DES I GNER/CONTRACTOR: <br /> Villard Inc.Architects <br /> JOHN TERRANCE HOMES <br /> COMPLIANCE:Passes <br /> Maximum UA= ]095 <br /> Your Home UA=859 <br /> 21.6%Better Than Code(UA) <br /> Gross Glazing <br /> Area or Cavity Cont. or poor <br /> Perimeter R-Value R-Value U-Factor UA <br /> Ceiling 1: Flat Ceiling or Scissor Truss 3800 44.0 1.8 99 <br /> Wall l: Wood Frame, 16"o.c. 430 11.6 0.9 33 <br /> Door 1: Solid 42 0.140 6 <br /> Wall 2: Wood Frame, l6"o.c. 178 18.2 2.5 6 <br /> Window 1: Above-Grade:Above Grade,Other 60 0310 19 <br /> Wall 3: Wood Frame, 16"o.c. 110 18.2 2.5 5 <br /> Window 2: Above-Grade:Above Grade,Other 22 0310 7 <br /> Wall 4: Wood Frame, 16" o.c. 116 18.2 2.5 2 <br /> Door 2: Glass 78 0.140 11 <br /> Wall 5: Wood Frame, 16"o.c. 1570 18.2 2.5 74 <br /> Window 3:Above-Grade:Above Grade,Other 220 0.310 68 <br /> Wall 6: Wood Frame, 16"o.c. 386 18.2 2.5 10 <br /> Window 4:Above-Grade:Above Grade,Other 212 0.310 66 <br /> Wail 7: Wood Frame, 16" o.c. 1002 18.2 2.5 36 <br /> Window 5:Above-Grade:Above Grade,Other 352 0.310 109 <br /> Wall 8: Wood Frame, 16"o.c. 386 18.2 2.5 13 <br /> Window 6: Above-Grade:Above Grade,Other 96 0.310 30 <br /> Door 3: Solid 50 O.140 7 <br /> Basement Wall l: Wood Frame 433 11.6 4.3 17 <br />