� �i2HVi�C�Residential 8 Light Commercial HVAC Loads -,, Elite Software Development,Inc.'',
<br /> !, PlGrrzouth Plumbing&Heating '' John Terrance Homes- I
<br /> j B�ooklyn Center, MN 55428-1662 � rage 1
<br /> --- ___._ _
<br /> _ _
<br /> ' Total Building Summary Loads 'I
<br /> Component Area Sen Lat Sen Total � !
<br /> ' Description Quan Loss Gain Gain Gain ' �
<br /> 3D Window Double Pane Low Emit Wood Frame 199 5,891 0 3,582 3,582 '
<br /> 11 C Door Metal Polystyrene Core 42 1,619 0 367 367 �'
<br /> 121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 2216 9,995 0 2,266 2,266
<br /> 15G Wall 5'or More Below Grade 8/12" BIk+R-11 739 2,605 0 0 0 I
<br /> 161 Ceiling R-44 Insulation 1901 3,585 0 1,705 1,705 ��,
<br /> 21A Basemt Floor 2' or More Below Grade 1896 3,731 0 0 0 ''
<br /> Subtotals for structure: 27,426 0 7,920 7,920
<br /> People: 6 1,380 1,800 3,180
<br /> Equipment: 300 1,200 1,500
<br /> Lighting: 0 0 0
<br /> Ducfinrork: 6,567 0 0 0
<br /> Infiltration: Winter CFM: 161, Summer CFM: 215 14,123 4,531 3,445 7,976
<br /> Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336 I
<br /> Sensible Gain Total: 15,806
<br /> Temperature Swing Multiplier: X 1.15
<br /> Total Building Load Totals: 55,992 8,106 18,177 26,283
<br /> ' Check Figures _ ' ' , ,�
<br /> __ - -- - - -
<br /> Total Building Supply CFM: 902 (1.7 AC/hr) CFM Per Square ft.: 0.237
<br /> Square ft. of Room Area: 3,797 Square ft. Per Ton: 1,293
<br /> - _.. _ _�..__- _ __
<br /> �Buildi�g Loads_ _ _ _._ �
<br /> ---- - ---. _.......
<br /> Total Heating Required With Outside Air: 55,992 Btuh 55.992 MBH
<br /> Total Sensible Gain: 18,177 Btuh 69 %
<br /> Total Latent Gain: 8,106 Btuh 31 %
<br /> Total Cooling Required With Outside Air: 26,283 Btuh 2.19 Tons (Based On Sensible + Latent)
<br /> 2.94 Tons (Based On 77% Sensible Capacity)
<br /> Notes----
<br /> _ --- _ _
<br /> ---
<br /> Calculations are based on 7th edition of ACCA Manual J.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads. I
<br /> C:\Elite\Rhvacw\Projects\John Terrance Homes-2460 Sandstone Ln -Orono.rhv Thursday, January 15, 2004, 3:23 PM