� RH�AC-Residential&Light Commercial HVAC Loads , Elite Software Development,Inc. ',
<br /> Plymouth Plumbing&Heating John Terrance Homes-"
<br /> � Brooklyn Center, MN 55428-1662 Pa�e 1 ,I �
<br /> _ __ . _ _ _ _ _ _ _ _ _
<br /> ! Total Building Summary Loads �
<br /> _ ._-_ - -: _ � _ � _
<br /> Component Area Sen Lat Sen Total
<br /> � Description Quan Loss Gain Gain Gain
<br /> 3D Window Double Pane Low Emit Wood Frame 199 5,891 0 3,582 3,582
<br /> 11C Door Metal Polystyrene Core 42 1,619 0 367 367 ,
<br /> 121 Wall R-19+ 1/2"Asphlt Board(R-1.3) 2216 9,995 0 2,266 2,266 I
<br /> i 15G Wall 5' or More Below Grade 8/12" BIk+R-11 739 2,605 0 0 0 I
<br /> I161 Ceiling R-44 Insulation 1901 3,585 0 1,705 1,705
<br /> I 21A Basemt Floor 2'or More Below Grade 1896 3,731 0 0 0 I
<br /> I Subtotals for structure: 27,426 0 7,920 7,920 �
<br /> i People: 6 1,380 1,800 3,180
<br /> j Equipment: 300 1,200 1,500 �
<br /> i Lighting: 0 0 0
<br /> j Ductwork: 6,567 0 0 0 �
<br /> � Infiltration: Winter CFM: 161, Summer CFM: 215 14,123 4,531 3,445 7,976 �
<br /> i Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336 I,
<br /> i Sensible Gain Total: 15,806 I
<br /> � Temperature Swing Multiplier: X 1.15 II
<br /> I Total Building Load Totals: 55,992 8,106 18,177 26,283 I
<br /> � _ _ _ _ _ - _ _ , I
<br /> � Check Figures , ' ,: ' � �
<br /> Total Building Supply CFM: 902 (1.7 AC/hr) CFM Per Square ft.: 0.237 I
<br /> Square ft. of Room Area: 3,797 Square ft. Per Ton: 1,293
<br /> _ _ _____ _ _ _ . _ - I
<br /> i Buildi�g Loads _ _ _ _: ' j
<br /> ___ _ _ _ - . �. _ _..� .�__� � �_.____
<br /> Total Heating Required With Outside Air: 55,992 Btuh 55.992 MBH �
<br /> Total Sensible Gain: 18,177 Btuh 69 % �
<br /> Total Latent Gain: 8,106 Btuh 31 % i
<br /> Total Cooling Required With Outside Air. 26,283 Btuh 2.19 Tons (Based On Sensible+ Latent) I
<br /> 2.94 Tons (Based On 77% Sensible Capacity) �
<br /> ' Notes -_ - - - _ - i
<br /> _ _ _ _ _ - - - -_- _ _- __ _ - � - -__- ---- ----
<br /> Calculations are based on 7th edition of ACCA Manual J. I
<br /> All computed results are estimates as building use and weather may vary. �,
<br /> Be sure to select a unit that meets both sensible and latent loads. j
<br /> �i
<br /> i
<br /> L _ - - -- - - - - - - - - - - - _ _ __ _ _ _ _- - - - - - _ _ - - - - - - - -
<br /> C:\Elite\Rhvacw\Projects\John Terrance Homes-2460 Sandstone Ln -Orono.rhv Thursday, January 15, 2004, 3:23 PM