Laserfiche WebLink
-__ _ <br /> _ - -__ ___-- --___ _ _ _--- --______ <br /> RHVAC-Residential HVAC Load Calculations -, Elite Software Development, Inc. <br /> Flare Heating &A/C Inc. � 2-Story Townhome End Unit BB <br /> Golden Valley MN_55427-3700 __-- -- ___---- __ ' --- -_ - - - _ _ _ __Pa9e_2.. <br /> _ _ _ __ _ _ - -- <br /> S,�sfem 1 Im orted Summar Loads re� �n � <br /> ( _ p _ ) __ Y : _ -._ �-� � _ � (•�n i ,f' <br /> Component Area Sen Lat Sen Total <br /> Description Quan Loss Gain Gain Gain <br /> ----- - - --_-- ._ _____ ___ _ _ __ <br /> 4A Window Double Pane & Storm Clear Glass Wood Frame 325 10 194 0 9,346 9.346 <br /> 8M Glass Door pouble Clear Glass Wood Frame 64 3,244 0 1,920 1,920 <br /> 11 C Door Metal Polystyrene Core 40 1,730 0 363 363 <br /> 121 �1/all R-19 + 1/2"Asphlt Board(R-1.3) 1542 7,803 0 2,001 2,001 <br /> 131 Part R-19 + 1/2"Asphlt Board(R-1.3) 265 1,341 0 219 219 <br /> 15G Wall 5' or More Below Grade 8/12" BIk+R-11 396 1,566 0 0 0 <br /> 161 Ceiling R-44 Insulation 1060 2,243 0 1,073 1,073 <br /> � 20J Floor Over Open Crawl Carpet + R-30 615 1,980 0 323 323 <br /> 21A Basemt Floor 2' or More Below Grade �156 1,007 0 0 0 <br /> _ - --._ - ----- -- <br /> Subtotals for structure: 31,108 0 15,245 15,245 <br /> People: 6 1,380 1,800 3,180 <br /> Equipment: 300 1,200 1,500 <br /> Lighting: 0 0 0 <br /> Ductwork: 1,532 0 0 0 <br /> Infiltration: Winter CFM: 159, Summer CFM: 80 15,659 1,893 1,702 3,595 <br /> Ventilation: Winter CFM: 125, Summer CFM: 125 12,273 2,968 2,668 5,636 <br /> Sensible Gain Total: 22,615 <br /> Temperature Swing Multiplier: X 1.00 <br /> - ---- __ <br /> System 1 (Imported) Load Totals: 60,572 6,541 22,615 29,156 <br /> - . , <br /> Check Figures ' <br /> __ -- _ --- - -- -_ _ -_.. -- - - _ --- -- <br /> Supply CFM: 935 CFM Per Square ft.: 0.364 <br /> Square ft. of Room Area: 2,570 Square ft. Per Ton: 1,057.746 <br /> System Loads <br /> _ ___ ___ __ . _. _ <br /> - -- _. __ ___ _ -_�__ _ <br /> Total Heatirg Required VVith Ou±side Air: 60,572 Btuh 60.572 MBH <br /> Total Sensible Gain: 22,615 Btuh 78 % <br /> Total Latent Gain: 6,541 Btuh 22 % <br /> Total Cooling Required With Outside Air: 29,156 Btuh 2.430 Tons (Based On Sensible + Latent) <br /> 2.513 Tons (Based On 75% Sensible Capacity) <br /> _ _ _ _ � ._ . _ <br /> Notes <br /> - .-- - --- -__ __--.__.-- --. _-.-------=-- ----__-------- - <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> I� <br /> i ' <br /> i � <br /> , S:\FHDATA\PROJECTS\Z&B\stonebay2stycondoBBendunit.rhv Monday, October 30, 2006, 9:35 AM <br /> � <br />