2011-01171 - sprinkler system
Orono
>
Property Files
>
Street Address
>
C
>
Cobblestone Court
>
2470 Cobblestone Court - 33-118-23-11-0080
>
Permits/Inspections
>
2011-01171 - sprinkler system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:44:31 PM
Creation date
4/20/2016 11:38:11 AM
Metadata
Fields
Template:
x Address Old
House Number
2470
Street Name
Cobblestone
Street Type
Court
Address
2470 Cobblestone Court
Document Type
Permits/Inspections
PIN
3311823110080
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. , <br /> Page 1 <br /> GREAT ROOM Date <br /> HYDRFULIC DESIGN INFORMATION SHEET <br /> Name - STONE BAY OF ORONO Date - 9-12-2011 <br /> Location - 2470 COBBLESTONE ORONO <br /> Building - GREAT ROOM System No. - 1 <br /> Contractor - LIFESAVER FIRE PROTECTION Contract No. - <br /> Calculated By - DOUG CARLSON Drawing No. - 1 <br /> Construction: (X) Combustible ( ) Non-Combustible Ceiling Height <br /> OCCUPANCY - RESIDENTIAL <br /> S Type of Calculation: ONFPA 13 Residential ONFPA 13R (X)NFPA 13D <br /> Y Number of Sprinklers Flowing: ( ) 1 ( ) 2 ( ) 4 ( ) <br /> S ( )Other <br /> T ( ) Specific Ruling Made by Date <br /> E <br /> M Listed Flow at Start Point - 14.0 Gpm System Type <br /> Listed Pres. at Start Pcint - 10 . 1 Psi (X) Wet ( ) Dry <br /> D MAXIMUM LISTED SPArTNr 14 x 14 O P�luge O PreAction <br /> E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle <br /> S Additional Flow Added - 0 Gpm Make TYCO Model LFII <br /> I Elevation at Highest Outlet - 10 Feet Size 1/2 K-Factor 4. 4 <br /> G Note: Temperature Rating 155 <br /> N <br /> Calculation Gpm Required 28.20 Psi Required 48.98 AT CITY <br /> Summary C-Factor usecl: Overhead 150 Underground 140 <br /> W Water Flow Test: Pump Data: Tank or Reservoir: <br /> A Date of Test - 9-2011 Rated Cap. Cap. <br /> T Time of Test - @ Psi Elev. <br /> E Static (Psi) - 65 Elev. <br /> R Residual (Psi) - 54 Other Well <br /> Flow (Gpm) - �014 Proof Flow Gpm <br /> S Elevation - <br /> P Location: AT SITE <br /> P <br /> L Source of Information: CITY WATER DEPT <br /> Y <br />