My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01234 - sprinkler system
Orono
>
Property Files
>
Street Address
>
C
>
Cobblestone Court
>
2450 Cobblestone Court - 33-118-23-11-0082
>
Permits/Inspections
>
2015-01234 - sprinkler system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:44:35 PM
Creation date
4/20/2016 9:52:04 AM
Metadata
Fields
Template:
x Address Old
House Number
2450
Street Name
Cobblestone
Street Type
Court
Address
2450 Cobblestone Court
Document Type
Permits/Inspections
PIN
3311823110082
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> Technical Data: F1Res 30 Pendent and Recessed Pendent(SIN R3511) <br /> _ _ _ _ -- - - <br /> Thread ' NominalOrifice � Max. � Sprinkler Max. Actual Sprinkler <br /> Size Inch(mm) , Pressure Temp.Ratin.g Ambient Temp. K Length <br /> _ � ,__ psi jbarj_ °F °C °F � °C Factor ---- Inch_(mmj___.._. <br /> N�� - �h,'(8.2) 175(12) 155_ 1 68 � 100 38 3.0 2.25(57) <br /> (R'"�_ !_ __ 175 7�3 . _ _ ' __ '' <br /> '`"Baseline flows and pressures for 0.05 density <br /> - ---- ------ ' P . . � <br /> I Max,Coverage area Max. ��5°F/68°C� 9 __ (175°Fl79°C) 9 ' To of Deflector I Minimum <br /> Ordinar Tem Ratin Intermediate Tem atin <br /> Ft x Ft(m x m) Spacing Flow Pressure Flow Pressure to Ceiling I Spacing , <br /> Ft(m) Inch(mm) � Ft(m) <br /> GPM Umin� __ PSI(bar) GPM(Umin� � PSl�bar _1_ <br /> 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) ', 7.0(0,4f3) 8(30,3) 7.0(Q48) 1 to 4(25 to 100); ' ', <br /> ; } _ __ . _ _ __ _ _ __ Yl recessed using 8(2,4) ' <br /> 14 x 14(4,3 x 4,3j 14(4.3) i 10(37,8j , 11 (0,76) 10(37 8) 11 (0,76) ' F2 escutcheon I , <br /> , <br /> --- - ---- '-- - __i----- �-----.. <br /> For Ceiling types refer to NFPA 13, 13R or 13D <br /> ''`Calculate for a .10 density but in no case go below the baseline flows& pressures <br /> Technical Data: F1 Res 49 Pendent and Recessed Pendent <br /> Nominal Sprinkler Max. Max. A�a��Sprinkler Escutcheon", Fi or F2, Data: <br /> Thr�d Orifice Temp. Pressure Ambient K � Length Face of fitting to <br /> Size Inch Ratin psi Tem . Inch T Adjustmerrt "A" ��in <br /> mm °F ; °C bar °F o� Factor mm y� Inch(mm) Inch(mm) �nch m <br /> 'h"NPT 155 I 68 100 38 Min.=�(4(19.1) 3h�:-,�hE <br /> (R/�) ��� �11) 175 79 175(12) 1� � 4,9 2.25(57) Fl 'k (19.0) , ., <br /> Max.=1 J.(38.1 (4.7-24.0) <br /> '"Baseline flows and pressures for 0.05 density r2 y,,��12�� Min.=�`/�E('ra.a) '/��-"l,s <br /> M�.=1'/z{38.1) (4.7-17.4) <br /> 'Note:Escutcheons F1 or F2 may be used with <br /> Deflector-to-ceiling Model F1 Res 49&58 Recessed Pendent Sprinkler <br /> Maximum 1" (25mm)to 4"(100mm) *Deflector-to-ceiling <br /> ' Ma�c.Sprinkler Sprinlder Maximum 4"(100mm)to 8"(203mm) <br /> Flow Pressure <br /> Spacing g�(�� ����r� Identification Max.Sprinlder i �ow p��� Sprinkler <br /> ft m Number SI Spacing � m L m si bar lderrt'rfication <br /> 12 x 12(3 6x3.6) 13(49) 7.0(0.48) ft m ' 9P � P � p � } Number SIN <br /> 14 x 14(4.3x4.3) 13(49) 7.0(0.48) 12 x 12(3.6x3.6) 15(57) 9.4 0.65 <br /> 16 x 16(4.9x4.9 13(49 7.0 0.48) R3516 14 x 14(4.3x4.3) , 16(60.5) 10.6(0.73) <br /> 18 x 18(5.5x5.51 17(64.3) 12.0(0.83 16 x 16(4.9x4.9) �, 17(64.3) 12.0(0.83) R3516 <br /> 20 x 20(6.1 x6.1) 20(75.7 167('1.14 18 x 18(5.5x5.5) 19 72) 15.0(1.0) <br /> 20x20(6.1x6.1) 22(83.2) 20.2(1.4) <br /> 'Note:The F1 Res 49 pendent and recessed pendent residential <br /> sprinklers can be insialled per NFPA 13 in beamed ceilings <br /> meeting the following criteria: <br /> 1. Maxlmum beam depth=7"(178mm) <br /> 2. Beam spacing at or greaier than 7.5 ft.(2.3m)on center. <br /> Technical Data: F1 Res 58 Pendent and Recessed Pendent <br /> Sprinkler Temp. Max. <br /> Thread Size Nominal Orifice Rating Max. Pressure Ambient Temp. K Sprinkler Length <br /> Inch(mm) aF oC psi(bar) oF oC Factor Inch(mm) <br /> 155 68 100 38 <br /> '/�"NPT(R!h) Y�°(13) 175 79 175�12� 150 66 5.8 225(57) <br /> **Baseline flows and pressures for 0.05 density <br /> Max.Sprinkler Spacing Flow Pressure Ceiling-to-Deflector Sprinkler ldentification <br /> ft(m) gpm(Lpm) psi(bar) Inch(mm) Number(SIN) <br /> 12 x 12(3.6x3.6) 16(61) 7.6(0.53) <br /> 14 x 14(4.3x4.3) 16(61) 7.6(0.53) <br /> 16 x 16(4.9x4.9) 16(61) 7.6(0.53) �25 4��� R3513 <br /> 18 x 18(5.5x5.5) 19(72j 10.II(0.75) <br /> 20 x 20(6.1x6.1} 22(83.3) 14.4(1.0) <br /> '*Calculate for a .10 density but in no case go below the baseline flows& pressures <br /> 4. <br />
The URL can be used to link to this page
Your browser does not support the video tag.