Laserfiche WebLink
����E��� <br /> f�ew Construction Energy Code Compliance Certificate �sJ.�s �, (�: �����j <br /> Per Nl]01.8 Building Certificate.A building ceRificate shall be posted in a permanently visible location inside Date Certificace Posced <br /> the building. The certificate shall be completed by the builder and shall list informa[ion and values of <br /> components listed in Table N1101.8. /'�I��O <br /> Mailing Address of the Dwelling or Dwelling Unit City v <br /> logo here <br /> 2450 Cobblestone Court Orono <br /> Name of Residential Contractor MN License Number <br /> Wooddale Builders BC002926 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type: Check All That Apply X Passive(No Fan) <br /> o � <br /> �, c <br /> � � Active(With fan and monometer or <br /> Q���O GOPY T � <br /> F" � >, other system monrtoring device) <br /> td U C b 0. GJ <br /> o a 3 U — o � <br /> � p, O � � J D <br /> � Q �..� y '�O C <br /> � C Q� m O � p � T <br /> Insulation Location � o z � � v p � w o <br /> �a o � � ; �v v <br /> `d � ° °' °� c�a c�`a � on o� <br /> F ° z v:. w u�, w° � x cx Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall R-15 X R10 Ext. & R5 Int. <br /> Perimeter of Slab on Grade X <br /> Rim Joist(Foundation) f2-2� X Spray Foam <br /> Rim Joist(15�Floor+) X <br /> wau R-21 X <br /> Ceiling,flat R-49 X <br /> Ceiling,vaulted R-49 X <br /> Bay Windows or cantilevered areas R-38 X AISo 3/4" Foam below <br /> Bonus room over garage X <br /> Describe other insulated areas <br /> Windows 8 Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: 0.31 X Not applicable,all ducts located in conditioned space <br /> Solaz Heat Gain Coefficient(SHGC): 0.33 <br /> MECHANICAL SYSTEMS Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> F�e��ryPe Natural Gas Electric Electric P�s��e <br /> Manufacturer Rheem Rheem Rheem Powered <br /> Interlocked with exhaust device. <br /> Model R92PA0601317MSA $ZV50-2 13AJN36A01 Describe: <br /> Input in 56,000 Capaciry in so Output in 3 Other,describe: <br /> Rating or Size BTUS: Gallons: Tons: <br /> Heat Loss: 49,072 Heat 31,757 Location of duct or system: <br /> Structure's Calculated Gain: <br /> AFUb or 92 SEER: 13 <br /> HSPF% <br /> Calculated 34,200 <br /> Efficienc cooling load: Cfm's <br /> "round duct OR <br /> Mechanical Ventilafion Sysfem "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.rivo furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): X Not required per mech.code <br /> Select Type Passive <br /> x Heat Recover Ventilator(HRV) Capacity in cfins: Low_ 75 High: 150 Other,describe: <br /> Energy Recover Ventilator(ERV)Capaciry in cfms: Low: High: Location of duct or system: <br /> Continuous e�austing fan(s)rated capacit}�in cfms: <br /> Location of fan(s),describe: Bathroom Cfm's <br /> Capaciry continuous ventilation rate in cfms: 65 CFM "round duct OR <br /> Total ventilation(intermittent+continuous)rate in cfms: 130 CFM "metal duct <br /> Created by BAM version 052009 <br />