Laserfiche WebLink
. , <br /> «����� <br /> , . - <br /> 1. All hC►TI5 Ore to be completed per Edward Jones Specificatio�s (see Ezhibit 8) unless noted otherwise <br /> on these poges. <br /> , � 2. GONTRACTOR to field verify vll existin9 conditions; if there are ony chon9es, revisions or disc�epancies <br /> pleose rAll: 800-82a�6525 <br /> •Existing and new partition dimension maximum tolerance is 4" unless noted os HO�D. <br /> 3. Londlord/Contractor to provide sepa�ate NVAC controls for Edward Jones spoce. <br /> 4. Controctor to provide new electrical dev�ces as indicated on pbn if on existing device is not within 36' <br /> Of device in�cated. • Do not remove devices that ore existing in rem0ining wolls, unless noted. Verif <br /> existing devices are in good working condifion. <br /> 5. A switch shall occur ot each egress door, ond sholl be 3-way if opplicable for multiple entrances. <br /> 6. Mechanicol, E(ectrical, and Plumbing (MEP) are all Design/Build: MEP contractors are required to obtain <br /> oll required drawings, permits, etc. rebted to their work. <br /> 7. ControCtor to provide and install Exit/Emergency bghts as requi�ed by Iocol building codes. <br /> 8. Contractor to install CAT6E phone lines (number as shown on Sheet 2 of 3) in �" conduit as required <br /> by IoCol code from building souree (O�lurk� to BOC server bcation as indicated on plan by symbol�. <br /> 2'-0-.r-0'F11r vl•o�o, <br /> ELECTRICAL DETAIL ,�,��:v b <br /> 3/e•=�'-o• <br /> �nr�.(a��9 �cav).c r <br /> wd�6}oMd.4�b Oi <br /> ka�lY� <br /> ��!a9 0�+� w�(0�M pd <br /> (OC r rvn ylen�In�la NN i};,y y,,,,�1,md, <br /> caidiA rvn uilcal� <br /> General Controctor {GC) to verify existence vnd functionality of sign circuit along sign ban serving <br /> subject spoce. Existing circuit must be located in�on the sign bon above the subject spoce and withi <br /> six feet (6') ot the centerline of the space. The circuit should be a direct feed from the electr�col <br /> ponel within the tenont spoce and be ied through a time clock or photocell. Should the c�rcuit not <br /> exist ond�o� be deemed nanfunctional, GC to provide instcllotion of new dedicoted sign ��r�uit, photocel <br /> ond junction box to be mounted within the sign ban no more that six feet (6') from the centerline of <br /> the subject space. Cost for installation of the circuit, junction box and photocell to be included in the <br /> bose electricol bid for the �o'ect. <br /> KEY PLAN - : *Pu�N NOT To s�a�E* ** CONTRACTOR MUSY <br /> CITY O� OR���x HAVE (3} PAGES FOR <br /> evi�o��. , :_�;,��;� �•..���� r;���, ,�.�� � ��� � <br /> fNSPECfGA IQ�,__ ._ _,-,� � ��.���� THIS SEf OF <br /> _ ,: - —���} ' <br /> DA�E__ I zz_o�--- __--- _ .. .. ._ - --- DRAWINGS. IF YOU <br /> �f�j'"�-t�''�`r��-�'� ���'� ��` 5ite �Plan IS n0� ARE MISSING ANY <br /> ❑ c �c�� � :,r�, . �.;� PAGES, PLEASE <br /> ❑ r , r�n �� , t7vc�il�l���r <br /> �r� .. ��....: ...,. . ,_ , ��,_.. . > ; . ���ti,o CONTACT DESIGNER A <br /> in ru�i I� � - ����. 80�-824-6525 <br /> RbS.L �..,�,� ,:�; M � ..,�.:t � r;�...a� .;°::�c � n,s,evie�.H. P <br /> I:EGP i i-tl��-�,"' SET'C:v 3t i�AT AI.L 7f��1�5 " Edward,�neS <br /> ��.OV l�/Ye � �'�A^i✓a r C� �►�✓1i1� IN� ST�4 L L <br /> ,v BRANCH FACILITIES <br /> �" � T � BUILDING lNFORMATION (CONSiRUCTION TYPE) BRANCH OFFICE 18945 <br /> First Floor, Non-Sprinklered 2395 Blaine Ave <br /> OCCUPANCY USE GROUP: 8-Business Novorre, MN 55392 <br /> OCCUPANCY LOAD: 1425 sf � 100sf/Person = 15 Persons LEASE SQ. Ff. 7 425 <br /> ISSU6 REVISIONS <br /> N0. DAiE DESCRP11oN <br /> t t-t6- R rcv�sons <br /> BUILDING OWNER/PROPERTY MANAGER CONTACT' z i-2e-o Nt �o�z�a .�nap. <br /> Bob Nard�ng �12-471-0153 (��,5Z,a <br /> LEASING COORDINATOR: <br /> Louie Tocco 314-515-3931 �eY� a EXHIBI7 A <br /> DESIGNER ea0-824--a52s s��r <br /> Zsuzso Csobanki 314-515-3963 �.,� ,i-i a-oe 1 ,� 3 <br /> ,I!: ", <br /> il I <br /> .il� �.� � '� <br /> .�,�Ii.�� ': �, � . <br />