Laserfiche WebLink
Rhvac Residential&Light Commercial HVAC Loads Elite Soflware Development,loc. <br /> West Metro Mechanical Inc. � 3460 Birch�ane,Orono, Mn <br /> Norwood,MN 55368 _ _ _ _ _ Pa�e 2 <br /> Project Report <br /> General Project Information ' --- - ! <br /> _--- -- _— ------- --- ----- ------------- - <br /> Project Title: 3460 Birch Lane, Orono, Mn <br /> Designed By: Andrew Franck <br /> Project Date: Wednesday, April 8, 2015 <br /> Client Name: M&M Home Contractors <br /> Client Address: PO Box 90 <br /> Client City: Cologne, Mn <br /> Company Name: West Metro Mechanical <br /> Company Representative: Andrew Franck <br /> Company Address: 220 Franklin St. <br /> Company City: Norwood, Mn 55368 <br /> -- — - <br /> Design Data . <br /> -- --- --- ----- _ -- . --- --- --- <br /> - <br /> Reference City: Minneapolis/St. Paul AP, Minnesota <br /> Building Orientation: Front door faces South <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Drv Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter: -11 -11.42 n/a n/a 70 n/a <br /> Summer: 88 71 44% 50% 75 24 <br /> --- --- ___. <br /> Check Figures _ -- --- ___ _ � <br /> -- _ _ _-- -------_ ___ ___ - - <br /> Total Building Supply CFM: 1,101 CFM Per Square ft.: 0.467 <br /> Square ft. of Room Area: 2,356 Square ft. Per Ton: 1,152 <br /> Volume (ft') of Cond. Space: 19,374 <br /> _- — <br /> -- --- - - - ---, <br /> Building Loads <br /> — ---- --- - --- _ --- -_ --- --------- --- -_ --- _ _--- ------- <br /> Total Heating Required Including Ventilation Air: 70,084 Btuh 70.084 MBH <br /> Total Sensible Gain: 23,495 Btuh 96 % <br /> Total Latent Gain: 1,052 Btuh 4 % <br /> Total Cooling Required Including Ventilation Air: 24,547 Btuh 2.05 Tons(Based On Sensible+ Latent) <br /> Notes <br /> ---- ---- - --- --_- -__ --- ----------- ------- ----- -..------ ---- <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> I <br /> �I <br /> i <br /> � <br /> C:\Users\Ste hanie\Documents\Elite Software\Rhvac 9 Pro�ects\Lisle-Orono.rh9 Wednesda ,A ril 8, 2015, 7:09 PM <br /> P 1 Y p <br />