My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-00031 - septic
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
350 Big Island - PID: 23-117-23-32-0039
>
Septic
>
2009-00031 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:13:20 PM
Creation date
4/18/2016 1:30:51 PM
Metadata
Fields
Template:
x Address Old
House Number
350
Street Name
Big Island
Address
350 Big Island
Document Type
Septic
PIN
2311723320039
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� ' Viw� <br /> _ �t. <br /> 1. Upslope VolUme+ Volume under rockbed+Downslope Volume <br /> a.Upslope Volume:(depth of clean sand+�)x{upsfope berm) x(mound length)I 2=ft3 <br /> 2.8 ft x 7.8 ft x 40.6 ft /2 = 443.4 ft3 <br /> b.Volume under rockbed: (average depth of sand under rock)x(rockbed widtli)x(mound length)=ft3 <br /> 3.0 ft x 10.0 ft x 40.6 ft = 1197.7 ft3 <br /> c.Dovwislope Volume: (depth of dean sand+1)x(downslope berm)x(mound length)12=ft3 <br /> 5.1 ft x 54.5 ft x 40.6 ft / 2 = 5642.4 ft3 <br /> Total cubic feek = 7283.4 ft3 <br /> 2. Divide ft�by 27 ft3tyd�to get cubic yards <br /> 7283.4 !27 = 269.8 yds3 <br /> 3. Multiply cubic yards by 1.4 to get weight of sand in tons <br /> 269.8 yds3 X 1.4 377.7 tons <br /> 4 Add 10°�for Constructability <br /> 377.7 tons x 1.1 = <br /> A-1 Estimated Sewage Flows in GPD <br /> No.of <br /> B�ms Class I Class II Class AI Class IV <br /> 2 3Q0 225 18(t 60%of <br /> 3 450 300 218 the <br /> 4 600 375 256 values <br /> 5 750 450 294 in the <br /> 6 9fl0 525 332 Class I, <br /> 7 �d50_ 600 370 II or II <br /> 8 1200 675 448 columns <br /> D-33 Absor ion wdth Sizin Table <br /> Perc Rate Sal Texture Lo�ng Rffie Absorption <br /> mpi gpolsq ft Ratio <br /> Coarse sand <br /> <5 Loamy sand 9.2Q 1.00 <br /> Med.,Fine sand <br /> 6-15 San loam 4.75 1.50 <br /> 16-30 Lo� O.SO 2.00 <br /> 31-45 SiltLoam,Silt 0.5d 2.40 <br /> 46-60 Clay loa►n,Silty a.45 2.67 <br /> or Sa CI Loam <br /> 61-120 Silty or Sandy <br /> Clay or Clay D24 5 <br /> >120* <br /> 'Must be ott►er or ance. <br /> Page 3 of 6 ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.