My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00133 - single family house
Orono
>
Property Files
>
Street Address
>
B
>
Bracketts Point Road
>
1220 Bracketts Point Road - 11-117-23-32-0018
>
Permits/Inspections
>
2016-00133 - single family house
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:29:43 PM
Creation date
4/18/2016 9:23:03 AM
Metadata
Fields
Template:
x Address Old
House Number
1220
Street Name
Bracketts Point
Street Type
Road
Address
1220 Bracketts Point Road
Document Type
Permits/Inspections
PIN
1111723320018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- Beam Design <br /> � RAM Concrete Beam v 14.07.01.01 Page 7/30 <br /> RAM Database: 2015-12-21 Hannaford DD 02/02/16 09:38:44 <br /> Building Code: IBC Concrete Code: ACI 318-1 l <br /> BEAM INFORMATION: EXTERIOR GRADE BEAM CONTROLLING CASE <br /> Stoiy Level Graund Floor <br /> Beam Number 71 Grid Location_ (52.12ft-24.33ft)-(52.12ft-32.62ft) <br /> Beam Line Number- 16 Span Number_ 3 <br /> Geometry <br /> Size:. _________ 5'-0" GB <br /> Depth (in) 60.00 Web Width (in) 12.00 <br /> Flange Width (in) NA Flange Thicicness(in) NA <br /> Length c-c (ft) 8.29 Clear Lenglh (ft) _ _ ._. _ __.._.__ _ 7.29 <br /> Left Support Length (in)- 12.00 Right Support Length (in) 12.00 <br /> Left Support Width (in) 12.00 Right Support Width (in) 12.00 <br /> MATERiAL PROPERTIES: <br /> Fc(ksi) 4.00 fy Longitudinal (ksi). ________. 60.00 <br /> fct(ksi) 0.00 fy Transverse (ksi) 60.00 <br /> Conc. Weight(pc�_-_-.__ 145.00 Conc. Type NWC <br /> Coilc. Modtilus (ksi) 3644.15 Reinf. Modulus(ksi) 29000.00 <br /> General Warning(s): <br /> Sectiov must be designed as a Deep Beam per ACI 318-11 for shear. Section must be designed as a Deep <br /> Beam per ACI 318-11 for flexural design. <br /> TOP LONGITUDINAL REINFORCEMENT: <br /> Start End End-Condition <br /> Set Sizc Num Depth Layer Supp. Loc. Supp. Loc. Start End <br /> (in) (ft) (ft) <br /> 4 #6 3 15.500 Upper 4 -7.208 4 6.792 Splice Splice <br /> Max. Bar Deptl�Limit(in): 57.625 Clear Bar Cover(in): Top: 1.500 Side: 1.500 <br /> BOTTOM LONGITUDINAL REINFORCEMENT: <br /> Start End End-Condition <br /> Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End <br /> (in) (ft) (ft) <br /> 3 #6 2 57.500 Lower 3 0.084 3 8.084 Splice Splice <br /> Max. Bar Depth Limit(in):- 57.625 Clear Bar Cover(in}: Bot.: 1.500 Side: 1.500 <br /> LONGITUDiNAL BAR DESIGN DETAILS: <br /> Positive Moment Negative Moment <br /> Loc. Mu eMn As req. As Mu eMn As req. As <br /> (ft) (Icip-ft) (lcip-ft) (inZ) (inz) (kip-ft) (kip-ft) (in2) (in2) <br /> 24.916 0.00 225.14 0.00 0.86 -20.72 -229.09 0.11 0.83 <br /> 25.416 0.00 225.14 0.00 0.59 -20.72 -252.85 0.11 0.65 <br />
The URL can be used to link to this page
Your browser does not support the video tag.