Laserfiche WebLink
Apr 29 14 10:42a Joseph Olson 763-498-8290 p.4 <br /> ' Property address: 3535 Chnsiine Drive,Orono,MN _ Inspector initialslDate: J.O.421/94 <br /> 4. Soil Sepd�dtlon—Compliance cornponent#4 of 5 <br /> Date of irtstatlation: 7114J88 ❑ Unknown Verification rnethod(s): <br /> ShorelandANellhead protectionlFood Beverege �Y2s ❑�Io <br /> Lodging? Soil o6servaSon does nof expire. Pr�vious soil <br /> observah'ons by two rndependent parties are sufficient <br /> Comp�iance criteria: unless site conditlons have been altered or JocaJ <br /> Forsystems built pnorfo Aprr!1, 9996, and ❑Yes �9uirements difler. <br /> ❑ No <br /> notlocafed in Shoneland orWellhead I ❑ Conducted soil obsenration(s)(Attach bonng togs) <br /> Profsc6on Area ornot serving a food, i ❑ Two previaus verifications(Anach 8onnglogs) <br /> beverage or lodging establ�shment� <br /> � Not appGcable(Holding tank(s),no drainheld} <br /> Drainfield has at least a two-foot vertical ❑ UnablB to verify(See Camments�ExpianationJ <br /> separation distance from periodically <br /> saturated soil or 6edrock. ; 0 Other(See Commeats/Explanation) <br /> Non perfonnance systems builfApril 1, i ❑Yes ❑No Comments/�xpJanatro�: <br /> 1996, or later or for non performance , <br /> sysfems focafed in Shoreland or WeUhead <br /> Protection Areas ar servrng a food, � <br /> beverage, orlodgingestabfishment: <br /> Drai�eld has a three-foot vertical <br /> separalion distance from periodica�ly <br /> saturated soil o�bedrodc." <br /> "Expenmental" "Other'; or "Performance" ❑Yes ❑No Indicate de ths �f eievations <br /> systems built under pre-2008 Rules;Type!V <br /> or V systems built under 2008 Rules(708(1. '. A. Bottorn of distribution media <br /> 2350or7080.2400 (Advanced Inspector -- <br /> License required) B. Periodicall saturated soiUbedrock <br /> Drainfield meets the designed vertical C. System separation <br /> separafion distance from periodically _— <br /> saturated soil or bedrock. <br /> � D. Required compliance se aration' <br /> Any"no"answer above�ndicates the system is •May be reduoed up to 15 percent if aaowed by Loca1 <br /> Failing fo Proteet Groundwater. Ordinance. <br /> 5. Operating Perr�it and Nitrvgen BMP�`—Compliance companent#5 of 5 � Not applicable <br /> Is the system operated underan Operating Permit? []Yes ❑ No If"yes",A below is required <br /> Is the system required to employ a Nitrogen BMP? ❑Yes ❑ No lf"yes", B below is required <br /> BMP=Best Management Pracfrce(s)spec�ed in the system design <br /> If the a�swer to 6oth questions is "no'; this section does not need to be comp/efed. <br /> Compliance criteria <br /> a. Operating Perrnit number_ ~ � <br /> ❑Yes ❑ No <br /> Have the Operating Permit requirements been met7 ; <br /> b. ts the required nitrogen BMP in place and properly functioninq? ; ❑Yes ❑ No <br /> Arry "no"answer indicates lVoncompliance. <br /> Upgrade Requirements(Minn.Staf. §i15.55J An imminent thrieaf to public health andsafety(ITPNSJ mustbe upgradeQ,replaceaf,orrts use <br /> disconbnued within ten monihs ofreceipt p1 this notice or within a shorter penoQ if 2quired 6y loca!ordinance. If the system is faifrng fo protect <br /> ground water,the system mus!be upgraded,repJac�e�or its use discpnfinued within the Gme required by loca!ordinance_!f an existrng system <br /> is not farling as defined in/aw, and has af feast Iwo feet of design soi/separation,fhen the system�ed rtot 6e upgraded,repaired; replaced, or <br /> its use disco�hnued,nohvrthstartding any lOca!o�inance that is more sfnct This provision does not apply to systems in shorefand areas, <br /> Wel/head ProtecLon Areas,or ihose used�n connection with food,beverage,artd lodging eslablrshmenfs as deftned in law. <br /> www.pca.stdte.mn.us • G51-296•6300 • 800-657-3864 . TTY 651-282-5332 or 800-657-3864 • Available in atternative tormats <br /> wq-mvists4-31 • 1/24l�2 Page 3 of 3 <br />