Laserfiche WebLink
/, � °� <br /> io 0 <br /> I � � CI'�CY of ORON� <br /> �r� f ,� _ � � <br /> �� "� 'n��7.�+ %j� ` � E.,�' Municipal Offices <br /> \� � ,,� , ,.r. . � <br /> ,� , ,�;`� , z :.�,,:�- �,,%, <br /> , Street Address: q5a—a4q'�6� � Maiiing Address: <br /> `'�':�`41�ESKpg'�;-�,:% 2750 Kel{ey Parkway P.O. Boz 66 <br /> ��--%' Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address:�� ����.(-' S•f'�tifC �� <br /> City Ordinance 199 requires that each existin�on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): I <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> ? "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and cons�vction standards of the current Orono <br /> Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may no[meet all the]ocation,design,or construction stanc}�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soi]characteristics. <br /> _� <br /> ` <br /> TANK CONDITION(5-7): �- <br /> Tank inspection indicates: <br /> � Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumped throuQh manhole and not through white inspection pipes. This allows for the proper <br /> cleaninQ Keep water softner and iron filter discharge out of septic svstem to prolona life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is stilt workin�in vour house. The alarm warns owner that septa�e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tanlc If <br /> tanks have not been pumped out within the last three years,they should be pumped out no�v. <br /> DRAINFIELD CONDITION(8-10): � <br /> 8 Drainfieid is dry,no surfacinQ evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly dischar�ing untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> �COMMENTS: <br /> � <br /> _ �' �— � _ �. <br /> ��- � -�.� <br /> Daie of Inspection Septic System Inspector <br />