My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-P10210 - new structure
Orono
>
Property Files
>
Street Address
>
C
>
Cherry Place
>
1430 Cherry Place - 08-117-23-33-0015
>
Permits/Inspections
>
2006-P10210 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:44:18 PM
Creation date
4/6/2016 3:22:38 PM
Metadata
Fields
Template:
x Address Old
House Number
1430
Street Name
Cherry
Street Type
Place
Address
1430 Cherry Place
Document Type
Permits/Inspections
PIN
0811723330015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � REWARDg <br /> � WALL SY8TEM8 �uild Different. Build Better.sM <br /> 6.1.2.3 <br /> Reward iForm Above-grade Wall <br /> Vertical Reinforcement Table For Wind Pressure <br /> Concrete: 3,000 psi Rebar: Grade 60 <br /> Design Maximum REBAR SPACING IN. --- <br /> Wind Wall Height 9" iForm 11" iForm <br /> Pressure Per Story (4" Fiat Wali) 6" Flat Wail <br /> (ps� (feet) #4 #5 #4 #5 <br /> 8 48 48 <br /> 20 9 48 48 <br /> 10 48 48 <br /> 8 48 48 <br /> 30 9 48 48 <br /> 10 42 48 48 <br /> 8 42 48 48 <br /> 40 9 36 48 48 <br /> 10 30 48 48 <br /> 8 36 48 48 <br /> 50 9 30 48 48 <br /> 10 6 12 42 48 <br /> 8 30 48 48 48 <br /> 60 9 18 24 42 48 <br /> � 10 Desi n Re 'd Desi n Re 'd 36 48 <br /> 8 24 36 48 48 <br /> 70 9 Desi n Re 'd Desi n Re 'd 36 48 <br /> 10 Desi n Re 'd Desi n Re 'd 30 42 <br /> 3 12 18 42 48 <br /> 80 9 Desi n Re 'd Desi n Re 'd 30 48 <br /> 10 Desi n Re 'd Desi n Re 'd 24 36 <br /> Notes: <br /> 1. For design wind pressures greater than 40 psf, all vertical wall reinforcement in the top Reward story <br /> shall be terminated with a 90-degree bend having a minimum length of 6 inches parallel to the <br /> horizontal wall reinforcement and lying within 4 inches of the top surface of the concrete wall. <br /> 2. Application must be within the specified design criteria. Consult an engineer for conditions beyond <br /> these assumptlons. <br /> 3. Place the vertical reinforcement in the center of the form as indicated in Details I-10 and I-11. <br /> a. The wall must be braced against sway at the top and bottom. <br /> 5. See accompanying Above-Grade Reinforcement Table Notes. <br /> 6-19 <br /> Issued on: 4/1/2003 <br /> Release: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.